Artigo
Coeficientes de perda de carga em valvulas e acessorios no escoamento laminar de fluidos nao-Newtonianos
Fecha
2000-01-01Registro en:
Ciencia and Engenharia/ Science and Engineering Journal, v. 9, n. 1, p. 78-82, 2000.
0103-944X
2-s2.0-0033684574
3761109299906668
0000-0002-2553-4629
Autor
Universidade Estadual Paulista (Unesp)
Resumen
Friction loss coefficients for laminar flow of xantan gum solutions (concentrations in the range of 0.1-0.5% by weight) through valves and fittings were experimentally determined. The rheological behavior, studied by means of a concentric cylinder rheometer, was pseudoplastic, being well described by the Ostwald-De Waele model with non-linear correlation coefficients (r) between 0.998 and 0.999. In the pressure drop measurements the following fittings were employed: completely open and half way open ball valve, completely open and half way open angle valve, tee used like coupling, tee used like a 90° elbow, short radius 90° elbow and coupling. The results showed that the friction loss coefficients increased with decreasing generalized Reynolds number. The friction loss coefficients could be well adjusted by a potential model, suggested by Kittredge & Rowley (1957) for Newtonian fluids, K f = A(Re g) -B, with correlation coefficients between 0.837 and 0.999.