dc.contributorUniversidade de São Paulo (USP)
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:01Z
dc.date.accessioned2014-05-20T13:43:41Z
dc.date.accessioned2022-10-05T14:06:41Z
dc.date.available2013-09-30T18:30:01Z
dc.date.available2014-05-20T13:43:41Z
dc.date.available2022-10-05T14:06:41Z
dc.date.created2013-09-30T18:30:01Z
dc.date.created2014-05-20T13:43:41Z
dc.date.issued2011-11-01
dc.identifierBrazilian Oral Research. São Paulo: Sociedade Brasileira de Pesquisa Odontologica, v. 25, n. 6, p. 506-511, 2011.
dc.identifier1806-8324
dc.identifierhttp://hdl.handle.net/11449/15258
dc.identifierS1806-83242011000600006
dc.identifierWOS:000311862200006
dc.identifierS1806-83242011000600006-en.pdf
dc.identifier9595871441940059
dc.identifier5341631901408733
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3890513
dc.description.abstractThe extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.
dc.languageeng
dc.publisherSociedade Brasileira de Pesquisa Odontológica (SBPqO)
dc.relationBrazilian Oral Research
dc.rightsAcesso aberto
dc.sourceWeb of Science
dc.subjectElectromyography
dc.subjectTemporal Muscle
dc.subjectMasseter Muscle
dc.subjectOcclusal Splints
dc.subjectDental Occlusion
dc.titleEffect of occlusal splint thickness on electrical masticatory muscle activity during rest and clenching
dc.typeArtigo


Este ítem pertenece a la siguiente institución