dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:29:42Z
dc.date.accessioned2014-05-20T13:43:24Z
dc.date.accessioned2022-10-05T14:05:54Z
dc.date.available2013-09-30T18:29:42Z
dc.date.available2014-05-20T13:43:24Z
dc.date.available2022-10-05T14:05:54Z
dc.date.created2013-09-30T18:29:42Z
dc.date.created2014-05-20T13:43:24Z
dc.date.issued2011-08-01
dc.identifierJournal of Oral Implantology. Lawrence: Allen Press Inc, v. 37, n. 4, p. 401-410, 2011.
dc.identifier0160-6972
dc.identifierhttp://hdl.handle.net/11449/15136
dc.identifier10.1563/AAID-JOI-D-10-00044
dc.identifierWOS:000294311700004
dc.identifier5581364193525500
dc.identifier9719883814872582
dc.identifier0000-0002-3800-3050
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3890416
dc.description.abstractThe aim of this study was to evaluate the stress distribution of different retention systems (screwed or cemented) associated with different prosthetic connections (external hexagon, internal hexagon, and Morse taper) in 3-unit implant-supported fixed partial dentures through photoelasticity. Six models were fabricated with photoelastic resin PL-2, and each model contained two implants of 4.0 x 10.0 mm. The models presented different retention systems (screwed and cemented) and different connections (external hexagon, internal hexagon, and Morse taper). The prostheses were standardized and fabricated in Ni-Cr alloy. A circular polariscope was used and axial and oblique (45) loads of 100 N were applied in a universal testing machine. The results were photographed and analyzed qualitatively with a graphic software (Adobe Photoshop). The screwed retention system exhibited higher number of fringes for both axial and oblique loadings. The internal hexagon implant presented better and lower stress distribution for both cemented and screwed prostheses. The oblique loading increased the number of fringes in all models tested. The cemented retention system presented better stress distribution. The internal hexagon implant was more favorable according to the biomechanical standpoint. The oblique load increased stress in all systems and connections tested.
dc.languageeng
dc.publisherAllen Press Inc
dc.relationJournal of Oral Implantology
dc.relation1.212
dc.relation0,569
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectdental implants
dc.subjectfixed partial denture
dc.subjectimplant-supported fixed partial denture
dc.titlePhotoelastic Analysis of Cemented or Screwed Implant-Supported Prostheses With Different Prostheses Connections
dc.typeArtigo


Este ítem pertenece a la siguiente institución