dc.contributorLa Pitie Salpetriere Hosp
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorZhejiang Univ
dc.contributorUniv Paris 06
dc.contributorDenis Diderot Univ
dc.contributorAvicenne Hosp
dc.contributorUniv Rech Expt
dc.contributorUniv Lille
dc.date.accessioned2014-05-20T13:32:02Z
dc.date.accessioned2022-10-05T13:36:56Z
dc.date.available2014-05-20T13:32:02Z
dc.date.available2022-10-05T13:36:56Z
dc.date.created2014-05-20T13:32:02Z
dc.date.issued2008-09-01
dc.identifierIntensive Care Medicine. New York: Springer, v. 34, n. 9, p. 1718-1723, 2008.
dc.identifier0342-4642
dc.identifierhttp://hdl.handle.net/11449/10928
dc.identifier10.1007/s00134-008-1126-4
dc.identifierWOS:000258562800026
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3886983
dc.description.abstractObjective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
dc.languageeng
dc.publisherSpringer
dc.relationIntensive Care Medicine
dc.relation15.008
dc.relation3,293
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectultrasonic
dc.subjectvibrating plate
dc.subjectnebulizer
dc.subjectnebulization of antibiotics
dc.subjectlung tissue concentration
dc.titleComparison of lung tissue concentrations of nebulized ceftazidime in ventilated piglets: ultrasonic versus vibrating plate nebulizers
dc.typeArtigo


Este ítem pertenece a la siguiente institución