Artigo
Sizing PZT Transducers in Impedance-Based Structural Health Monitoring
Fecha
2011-06-01Registro en:
IEEE Sensors Journal. Piscataway: IEEE-Inst Electrical Electronics Engineers Inc, v. 11, n. 6, p. 1405-1414, 2011.
1530-437X
10.1109/JSEN.2010.2098865
WOS:000289805300016
0534385574959094
Autor
Minist Educ Brazil
Universidade Estadual Paulista (Unesp)
Virginia Polytech Inst & State Univ
Resumen
A theoretical and experimental analysis regarding the correct size of PZT (Lead Zirconate Titanate) transducers used in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique is presented. Tests were carried out on aluminum structures using 5A and 5H PZT patches of various sizes. The results show that the sensitivity of SHM systems for damage detection can be optimized if the transducers are correctly sized according to the proposed procedure.