Artigo
Fatigue behavior of PVD coated Ti-6Al-4V alloy
Fecha
2011-06-01Registro en:
International Journal of Fatigue. Oxford: Elsevier B.V., v. 33, n. 6, p. 759-765, 2011.
0142-1123
10.1016/j.ijfatigue.2010.11.007
WOS:000288732400001
WOS000288732400001.pdf
6119671014416126
3511534795805776
Autor
Universidade Estadual Paulista (Unesp)
Brasimet Revestimentos PVD Ind SA
Resumen
The aim of the present work is to identify an environmentally clean coating process that will present lower influence in the Ti-6Al-4V fatigue strength. Axial fatigue tests of Ti-6Al-4V alloy TiN, CrN and WC:H (tungsten containing diamond-like carbon) Physical Vapor Deposition (PVD) coated was evaluated. Decrease in fatigue life was observed for coated specimens in comparison to base metal. Scanning Electron Microscopy technique was used to observe crack origin sites and coating thickness. DLC coating provides higher Ti-6Al-4V alloy PVD coated fatigue strength due to lower defects presence and the chromium interlayer, which acts as a barrier to fatigue crack propagation. (C) 2010 Elsevier Ltd. All rights reserved.