dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:23:11Z
dc.date.accessioned2022-10-05T13:10:12Z
dc.date.available2014-05-20T13:23:11Z
dc.date.available2022-10-05T13:10:12Z
dc.date.created2014-05-20T13:23:11Z
dc.date.issued2001-09-01
dc.identifierPesquisa Agropecuária Brasileira. Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA) Informação TecnológicaPesquisa Agropecuária Brasileira, v. 36, n. 9, p. 1145-1154, 2001.
dc.identifier0100-204X
dc.identifierhttp://hdl.handle.net/11449/6956
dc.identifier10.1590/S0100-204X2001000900008
dc.identifierS0100-204X2001000900008
dc.identifierS0100-204X2001000900008.pdf
dc.identifier9223246618159538
dc.identifier0000-0003-3839-0932
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3883995
dc.description.abstractEste estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.
dc.description.abstractThe aim of this study was to obtain the calibration curves for a TDR (Time Domain Reflectometry) equipment using five soils from the Piracicaba, SP, Brazil. The suitability of the built-in and generic calibration curves was also tested. Individual fitted curves for each soil showed determination coefficients (R²) of about 0.99 and the fitted curve for all five soils together showed a value of R² = 0.976. The standard error of estimate analysis has pointed out that generic curves are not suitable for more sensible applications, such as for absolute determination of soil water content. Comparison tests among fitted curves, generic curve and the equipment curve, pointed out that the first one is superior to the others. This study showed also that the equipment built-in calibration curve is not suitable for soil water content determinations for the five studied soils.
dc.languagepor
dc.publisherEmpresa Brasileira de Pesquisa Agropecuária (EMBRAPA)
dc.relationPesquisa Agropecuária Brasileira
dc.relation0.546
dc.rightsAcesso aberto
dc.sourceSciELO
dc.subjectpropriedades dielétricas
dc.subjectconteúdo de água do solo
dc.subjectinstrumento de medição
dc.subjectdielectric properties
dc.subjectsoil water content
dc.subjectmeasuring instruments
dc.titleCalibração de um equipamento de TDR para medida de umidade de solos