info:eu-repo/semantics/article
Internal rigid fixation in mandibular osteotomies: a comparative study using compressive mechanical testing
Comparação entre duas técnicas de fixação rígida por meio de ensaio mecânico de compressão
Author
Moraes, Anna Cecília
Oliveira, Marília Gerhardt de
Müller, Paulo Roberto
Polido, Waldemar D.
Gilapa, Genaro Mamani
Institutions
Abstract
The present study tries to evaluate in vitro, the resistence of rigid fixation with self-tapped bicortical screws, and the displacement of the bone fragments through a compressive mechanical testing, applyng an artificial compressive load to the segments of two groups of sagittal split osteotomies perfomed in fresch sheep mandibles. Osteotomies fixed with therr screws, at a 90 degrees angle to the lateral cortices, in a linear array were significantly more rigid than those fixed with two screws, at 60 degrees angle to the lateral cortices, in a linear array. O presente trabalho visa avaliar in vitro, por meio de um ensaio mecânico de compressão, a resisténcia da fixação rígida através do uso de parafusos bicorticais auto-rosqueáveis, e o deslocamento dos fragmentos ósseos submetidos á aplicação de uma carga artificial, em dois grupos de osteotomias Sagitais do Ramo realizadas em mandíbulas de carneiro frescas. As osteotomias fixadas por trés parafusos no padrão de posicionamento horizontal, com angulação de 90° com a cortical vestibular foram estatisticamente mais resistentes do que as fixadas por dois parafusos no padrão de posicionamento horizontal, com angulação de 60° com a cortical vestibular.