dc.creatorAdrados, B.
dc.creatorArias, C. A.
dc.creatorPérez, Leonardo Martín
dc.creatorCodony, F.
dc.creatorBécares, E.
dc.creatorBrix, H.
dc.creatorMorató Farreras, Jordi
dc.date.accessioned2020-03-10T23:24:07Z
dc.date.accessioned2022-09-29T16:31:29Z
dc.date.available2020-03-10T23:24:07Z
dc.date.available2022-09-29T16:31:29Z
dc.date.created2020-03-10T23:24:07Z
dc.date.issued2018
dc.identifierAdrados, B. et al. Comparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark [en línea]. Ecological Engineering. 2018, 124. doi:10.1016/j.ecoleng.2018.09.013 Disponible en: https://repositorio.uca.edu.ar/handle/123456789/9529
dc.identifier0925-8574
dc.identifierhttps://repositorio.uca.edu.ar/handle/123456789/9529
dc.identifier10.1016/j.ecoleng.2018.09.013
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3790126
dc.description.abstractAbstract: The aim of the present work was to evaluate and compare the performance in the removal of pathogenic microbes in four different types of decentralized wastewater treatment systems, namely: horizontal flow constructed wetlands (HFCW), vertical flow constructed wetlands (VFCW), biological sand filters (BSF) and biofilters (BF). All the systems analyzed are located in Jutland, Denmark. Water sampling took place during a three months period that covered from winter to spring. Conventional microbial indicators such as Escherichia coli, total coliforms (TC), intestinal enterococci and sulphite-reducing clostridia were quantified using traditional microbiological culture methods, whereas Bacteroides spp. determination was performed by quantitative PCR (qPCR). Other water quality parameters such as dissolved oxygen, biological oxygen demand (BOD5), total suspended solids (TSS), pH, temperature, ammonium concentration and conductivity of influent and effluent water samples were also analyzed. The results showed that bacterial indicators significantly reduced in all the systems analyzed. In general, BF showed the best performance in the removal of microbes for all bacteria studied, while BSF demonstrated an improved capacity to eliminate E. coli and TC. Contrarily, VFCW seems to be more effective reducing the amount of intestinal enterococci, sulphite-reducing clostridia, and Bacteroides spp. In the present study, HFCW were the less efficient wastewater treatment system for the elimination of the evaluated pathogens. However, the performance in the removal of microbes was still significant considering that such systems were the oldest under operation (with over 20 years of continuous task).
dc.languageeng
dc.publisherElsevier
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rightsAcceso abierto. 24 meses de embargo
dc.sourceEcological Engineering. 2018, 124
dc.subjectTRATAMIENTO DE AGUAS RESIDUALES
dc.subjectINGENIERIA SANITARIA
dc.subjectANALISIS DEL AGUA
dc.titleComparison of removal efficiency of pathogenic microbes in four types of wastewater treatment systems in Denmark
dc.typeArtículos de revistas