Trabajo de grado - Maestría
Calificación ante cargas dinámicas de una conexión entre una columna de guadua angustifolia y su cimentación
Fecha
2013Autor
Andrade Pardo, Sofía
Resumen
In this work we studied the behavior against horizontal forces of a connection between a column of Guadua Angustifolia Kunth and a foundation pedestal in reinforced concrete. Threaded rod bolts, both transverse and longitudinal, filling mortar and bands made with metal ribbons were used. Seven configurations were tested by varying the combination of the components of the connection in order to evaluate their influence on the structural response. For each configuration four specimens were built that were taken to the fault, one of them with monotonic loads and three with cyclic loads. It was found that the use of longitudinal bolts and mortar reduces both the strength and the ductility of the connection. Although the mortar filling improves the rigidity, it causes the connection failure to be fragile, which can be controlled if confinement ties are used. En este trabajo se estudió el comportamiento ante fuerzas horizontales de una conexión entre una columna de Guadua Angustifolia Kunth y un pedestal de cimentación en concreto reforzado. Se usaron pernos de varilla roscada, tanto transversales como longitudinales, mortero de relleno y zunchos elaborados con cintas metálicas. Se ensayaron siete configuraciones variando la combinación de los componentes de la conexión con el fin de evaluar su influencia en la respuesta estructural. Para cada configuración se construyeron cuatro especímenes que fueron llevados a la falla, uno de ellos ante cargas monotónicas y tres ante cargas cíclicas. Se encontró que el uso de pernos longitudinales y mortero reduce tanto la resistencia, como la ductilidad de la conexión. Aunque el relleno de mortero mejora la rigidez, genera que la falla de la conexión sea frágil, lo que puede controlarse si se usan zunchos de confinamiento.