Exergy study of air-conditioned space of a prototype scale of a river vessel room
Fecha
2016Registro en:
ASME International Mechanical Engineering Congress and Exposition, Proceedings (IMECE); Vol. 6B-2016
9780791850596
10.1115/IMECE2016-65093
Universidad Tecnológica de Bolívar
Repositorio UTB
56581610900
57194727134
56581727500
57194716721
Autor
Fajardo Cuadro, Juan Gabriel
Guerra M.A.
Sarria B.
Cruz O.
Resumen
The study was conducted on a scale prototype, which simulates one of the rooms in the real vessel air conditioning system. The main results are as follows: the higher the thermal load, the higher the exergy destruction, and increasing the average temperature in the room increases the exergetic efficiency and reduces the exergy destruction. There is an optimal thermal load per unit area of 214.074 W/m2. The highest exergetic efficiencies and lowest values of the exergy destruction indices occur when the average temperature of the room is in the comfort range recommended by ASHRAE, from 22 to 24°C. Copyright © 2016 by ASME.