dc.creatorCarrillo, Julián
dc.creatorRodríguez, Daniela
dc.creatorVillar-Salinas, Sergio
dc.date.accessioned2022-01-17T20:34:15Z
dc.date.accessioned2022-09-28T20:23:39Z
dc.date.available2022-01-17T20:34:15Z
dc.date.available2022-09-28T20:23:39Z
dc.date.created2022-01-17T20:34:15Z
dc.date.issued2021-07-12
dc.identifierJulian Carrillo, Daniela Rodríguez, Sergio Villar-Salinas, Contribution of CFRP to the shear strength of retrofitted lightly-reinforced concrete panels, Journal of Building Engineering, Volume 44, 2021, 102722, ISSN 2352-7102, https://doi.org/10.1016/j.jobe.2021.102722. (https://www.sciencedirect.com/science/article/pii/S2352710221005805)
dc.identifierhttps://hdl.handle.net/20.500.12585/10381
dc.identifier10.1016/j.jobe.2021.102722
dc.identifierUniversidad Tecnológica de Bolívar
dc.identifierRepositorio Universidad Tecnológica de Bolívar
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3727194
dc.description.abstractLow-rise buildings with thin Reinforced Concrete (RC) walls that do not comply with the minimum web shear reinforcement prescribed by current earthquake-resistant codes can be found in some Latin American countries. Previous experimental studies evidence that Carbon Fiber Reinforced Polymers (CFRP) strips may be used to retrofit RC walls for shear forces. The two models available in the literature to predict the contribution of CFRP to the shear strength of RC walls exclude key variables for assessing the seismic performance of lightlyreinforced concrete walls retrofitted with CFRP. In this research, a model for predicting the contribution of CFRP to the shear strength of lightly-reinforced concrete panels is initially developed. A model to correlate the contribution of CFRP to shear strength of lightly-reinforced concrete panels with that of thin and lightlyreinforced concrete walls is also proposed. The experimental program includes cyclic diagonal compression tests on fourteen lightly-reinforced concrete panels: one plain concrete panel and thirteen panels reinforced internally with web shear reinforcement-ratio equal to 0.11%; twelve retrofitted with CFRP, and one RC panel retrofitted with a concrete overlay conventionally reinforced with a welded-wire mesh. The CFRP configuration were diagonal or horizontal with one strip, and diagonal or horizontal with three strips. Three volumetric ratios of CFRP were studied in this research: 0.02%, 0.06% and 0.09%. The effectiveness of the configuration and volumetric-ratio of CFRP on performance of retrofitted panels was evaluated in terms of cracking patterns, failure modes, shear strength and energy dissipation capacity obtained from shear-strain curves measured during cyclic diagonal compression tests. The model proposed to predict the contribution of CFRP to the peak shear strength of retrofitted lightly-reinforced concrete panels depends on the properties, volumetric ratio and configuration of CFRP on the panel.
dc.languageeng
dc.publisherCartagena de Indias
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional
dc.sourceJournal of Building Engineering- vol. 44
dc.titleContribution of CFRP to the shear strength of retrofitted lightly-reinforced concrete panels


Este ítem pertenece a la siguiente institución