dc.date.issued2019
dc.identifierCaraballo D. y Caballero M. (2019) Estimation of soil resistivity by the assembly of a vertical electrical sounding equipment at a university campus at Turbaco, Bolivar. Journal of Physics: Conference Series; Vol. 1247, Núm. 1
dc.identifier17426588
dc.identifierhttps://hdl.handle.net/20.500.12585/9237
dc.identifier10.1088/1742-6596/1247/1/012010
dc.identifierUniversidad Tecnológica de Bolívar
dc.identifierRepositorio UTB
dc.identifier57211426694
dc.identifier57192237729
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3727001
dc.description.abstractA low-cost geoelectric equipment was implemented for academic purposes to carry out the Vertical Electrical Sounding method in order to determine the resistivity and depth of a point on the surface of a university zone and obtain the contrasts of that resistivity parameter for each type of soil. A model was reproduced at the laboratory to calibrate the equipment, and then the technique was tested in the field. Among the results, layers of sandy loam, soft limestone and dark clay with thicknesses of 0.3 m, 0.75 m and 12 m respectively were obtained, finally a clear clay was obtained whose thickness is unknown. These were compared with reference samples by well drilling method. There was a concordance between the results through the method of statistical confidence intervals with a normal distribution. The data behaved according to a soil model of lower-higher-lower resistivity. © Published under licence by IOP Publishing Ltd.
dc.languageeng
dc.publisherInstitute of Physics Publishing
dc.relation22 October 2018 through 26 October 2018
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial 4.0 Internacional
dc.sourcehttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85073887802&doi=10.1088%2f1742-6596%2f1247%2f1%2f012010&partnerID=40&md5=7fb19fafccd0834e18bf31e85f2510ff
dc.sourceScopus2-s2.0-85073887802
dc.source6th National Conference on Engineering Physics, CNIF 2018 and the 1st International Conference on Applied Physics Engineering and Innovation, APEI 2018
dc.titleEstimation of soil resistivity by the assembly of a vertical electrical sounding equipment at a university campus at Turbaco, Bolivar