dc.creatorPineda J.
dc.creatorVargas R.
dc.creatorRomero L.A.
dc.creatorMarrugo J.
dc.creatorMeneses J.
dc.creatorMarrugo A.G.
dc.date.accessioned2020-03-26T16:41:25Z
dc.date.accessioned2022-09-28T20:22:00Z
dc.date.available2020-03-26T16:41:25Z
dc.date.available2022-09-28T20:22:00Z
dc.date.created2020-03-26T16:41:25Z
dc.date.issued2019
dc.identifierPineda J., Vargas R., Romero L.A., Marrugo J., Meneses J. y Marrugo A.G. (2019) Robust automated reading of the skin prick test via 3D imaging and parametric surface fitting. PLoS ONE; Vol. 14, Núm. 10
dc.identifier19326203
dc.identifierhttps://hdl.handle.net/20.500.12585/9240
dc.identifier10.1371/journal.pone.0223623
dc.identifierUniversidad Tecnológica de Bolívar
dc.identifierRepositorio UTB
dc.identifier57192270016
dc.identifier57117284600
dc.identifier36142156300
dc.identifier6507678324
dc.identifier7004348301
dc.identifier24329839300
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3726555
dc.description.abstractThe conventional reading of the skin prick test (SPT) for diagnosing allergies is prone to inter- and intra-observer variations. Drawing the contours of the skin wheals from the SPT and scanning them for computer processing is cumbersome. However, 3D scanning technology promises the best results in terms of accuracy, fast acquisition, and processing. In this work, we present a wide-field 3D imaging system for the 3D reconstruction of the SPT, and we propose an automated method for the measurement of the skin wheals. The automated measurement is based on pyramidal decomposition and parametric 3D surface fitting for estimating the sizes of the wheals directly. We proposed two parametric models for the diameter estimation. Model 1 is based on an inverted Elliptical Paraboloid function, and model 2 on a super-Gaussian function. The accuracy of the 3D imaging system was evaluated with validation objects obtaining transversal and depth accuracies within ± 0.1 mm and ± 0.01 mm, respectively. We tested the method on 80 SPTs conducted in volunteer subjects, which resulted in 61 detected wheals. We analyzed the accuracy of the models against manual reference measurements from a physician and obtained that the parametric model 2 on average yields diameters closer to the reference measurements (model 1: -0.398 mm vs. model 2: -0.339 mm) with narrower 95% limits of agreement (model 1: [-1.58, 0.78] mm vs. model 2: [-1.39, 0.71] mm) in a Bland-Altman analysis. In one subject, we tested the reproducibility of the method by registering the forearm under five different poses obtaining a maximum coefficient of variation of 5.24% in the estimated wheal diameters. The proposed method delivers accurate and reproducible measurements of the SPT. © 2019 Pineda et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
dc.languageeng
dc.publisherPublic Library of Science
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial 4.0 Internacional
dc.sourcehttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85073657466&doi=10.1371%2fjournal.pone.0223623&partnerID=40&md5=ccacdcda607a2c484a1f971f08da2268
dc.sourceScopus2-s2.0-85073657466
dc.titleRobust automated reading of the skin prick test via 3D imaging and parametric surface fitting


Este ítem pertenece a la siguiente institución