dc.contributorFigueroa-Garcia J.C.
dc.contributorDuarte-Gonzalez M.
dc.contributorJaramillo-Isaza S.
dc.contributorOrjuela-Canon A.D.
dc.contributorDiaz-Gutierrez Y.
dc.creatorGrisales-Noreña L.F.
dc.creatorGarzón Rivera O.D.
dc.creatorMontoya, Oscar Danilo
dc.creatorRamos-Paja C.A.
dc.date.accessioned2020-03-26T16:33:09Z
dc.date.available2020-03-26T16:33:09Z
dc.date.created2020-03-26T16:33:09Z
dc.date.issued2019
dc.identifierCommunications in Computer and Information Science; Vol. 1052, pp. 214-225
dc.identifier9783030310189
dc.identifier18650929
dc.identifierhttps://hdl.handle.net/20.500.12585/9184
dc.identifier10.1007/978-3-030-31019-6_19
dc.identifierUniversidad Tecnológica de Bolívar
dc.identifierRepositorio UTB
dc.identifier55791991200
dc.identifier57212009687
dc.identifier56919564100
dc.identifier22836502400
dc.description.abstractIn this paper is proposed a master-slave method for optimal location and sizing of distributed generators (DGs) in direct-current (DC) networks. In the master stage is used the genetic algorithm of Chu & Beasley (GA) for the location of DGs. In the slave stage three different continuous techniques are used: the Continuous genetic algorithm (CGA), the Black Hole optimization method (BH) and the particle swarm optimization (PSO) algorithm, in order to solve the problem of sizing. All of those techniques are combined to find the hybrid method that provides the best results in terms of power losses reduction and processing times. The reduction of the total power losses on the electrical network associated to the transport of energy is used as objective function, by also including a penalty to limit the power injected by the DGs on the grid, and considering all constraints associated to the DC grids. To verify the performance of the different hybrid methods studied, two test systems with 10 and 21 buses are implemented in MATLAB by considering the installation of three distributed generators. To solve the power flow equations, the slave stage uses successive approximations. The results obtained shown that the proposed methodology GA-BH provides the best trade-off between speed and power losses independent of the total power provided by the DGs and the network size. © 2019, Springer Nature Switzerland AG.
dc.languageeng
dc.publisherSpringer
dc.relation16 October 2019 through 18 October 2019
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rightsAtribución-NoComercial 4.0 Internacional
dc.sourcehttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85075643487&doi=10.1007%2f978-3-030-31019-6_19&partnerID=40&md5=552715280abdfa8f09e4602ff1f9016c
dc.source6th Workshop on Engineering Applications, WEA 2019
dc.titleHybrid Metaheuristic Optimization Methods for Optimal Location and Sizing DGs in DC Networks


Este ítem pertenece a la siguiente institución