dc.contributorMendoza Castellanos, Luis Sebastián
dc.contributorGalindo Noguera, Ana Lisbeth
dc.contributorhttps://scienti.minciencias.gov.co/cvlac/visualizador/generarCurriculoCv.do?cod_rh=0000115302
dc.contributorhttps://scholar.google.es/citations?hl=es&user=S5TZbi8AAAAJ
dc.contributorhttps://orcid.org/0000-0001-8263-2551
dc.contributorhttps://www.scopus.com/authid/detail.uri?authorId=57193169160
dc.contributorhttps://www.researchgate.net/profile/Sebastian_Mendoza6
dc.contributorGrupo de Investigación Recursos, Energía, Sostenibilidad - GIRES
dc.creatorGaitán Álvarez, Juan Sebastián
dc.date.accessioned2020-09-30T18:56:49Z
dc.date.accessioned2022-09-28T19:16:12Z
dc.date.available2020-09-30T18:56:49Z
dc.date.available2022-09-28T19:16:12Z
dc.date.created2020-09-30T18:56:49Z
dc.date.issued2019-11
dc.identifierhttp://hdl.handle.net/20.500.12749/7262
dc.identifierinstname:Universidad Autónoma de Bucaramanga - UNAB
dc.identifierreponame:Repositorio Institucional UNAB
dc.identifierrepourl:https://repository.unab.edu.co
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3715643
dc.description.abstractEste trabajo propone modelar matemáticamente una planta solar térmica, implementando tecnologías Fresnel. El modelo global, está estructurado por dos ciclos termodinámicos, el primero es un ciclo de transferencia de calor que concentra la irradiación solar a través de espejos. El calor disponible en la superficie de los espejos es dirigido a un receptor ubicado en el punto focal, por donde fluye un aceite térmico orgánico (Therminol VP1), que alcanza temperaturas de trabajo de 400 °C. Para aprovechar el calor útil absorbido por el aceite térmico, se modeló la geométrica que permite determinar los ángulos que calculan la posición relativa del sol con respecto a la planta solar. Además, se modeló las dimensiones opto-geométricas para calcular el efecto sombra y la intercepción solar y la posición del receptor. Al ciclo de transferencia de calor se le integra un Ciclo Orgánico Ranking (ORC), que utiliza fluidos orgánicos refrigerantes. Los fluidos orgánicos utilizados son el R245fa, R600 y R236fa, debido a sus propiedades. Los balances de masa y energía en el ciclo de trabajo se realizaron de acuerdo a cada fluido seleccionado, donde se determinó la potencia generada por la turbina, la potencia consumida en la bomba y la eficiencia global del ciclo de trabajo. Los valores arrojados por el modelo de potencia eléctrica, están sujetos a la variación de parámetros, tales como: la temperatura ambiente, irradiación solar y velocidad del viento.
dc.languagespa
dc.publisherUniversidad Autónoma de Bucaramanga UNAB
dc.publisherPregrado Ingeniería en Energía
dc.relation[1] Superintendencia de Industria y Comercio, “ZONAS NO INTERCONECTADAS - ZNI Diagnóstico de la prestación del servicio de energía eléctrica 2017 Superintendencia Delegada para Energía y Gas Combustible,” no. 1, p. 74, 2017.
dc.relation[2] Greenpeace, “Energía Solar Térmica de Concentración,” 2009.
dc.relation[3] M. S. Hernandez, “Centrales Termosolares,” no. November, 2018.
dc.relation[4] M. A. Guillamon, Plantas termosolares de concentración
dc.relation[5] “Solar linear fresnel lens collector | 3D Warehouse.” [Online]. Available: https://3dwarehouse.sketchup.com/model/5ddab1f0ec50db4eff0aa907ecbc789b/Solar-linear-fresnel-lens-collector?hl=en. [Accessed: 29-Oct-2019].
dc.relation[6] K. Gouthamraj, K. J. Rani, and G. Satyanarayana, “Design and Analysis of Rooftop Linear Fresnel Reflector Solar Concentrator,” vol. 2, no. 11, pp. 66–69, 2013.
dc.relation[7] M. C. Suarez, “PLANTA DE POTENCIA ORC CON FUENTE DE ENERGÍA RENOVABLE,” 2018.
dc.relation[8] I. B. Askari and M. Ameri, “Solar Rankine Cycle (SRC) powered by Linear Fresnel solar field and integrated with Multi Effect Desalination (MED) system,” Renew. Energy, vol. 117, pp. 52–70, 2018
dc.relation[9] A. Rovira, R. Barbero, M. J. Montes, R. Abbas, and F. Varela, “Analysis and comparison of Integrated Solar Combined Cycles using parabolic troughs and linear Fresnel reflectors as concentrating systems,” Appl. Energy, vol. 162, pp. 990–1000, 2016
dc.relation[10] N. Velázquez, O. García-Valladares, D. Sauceda, and R. Beltrán, “Numerical simulation of a Linear Fresnel Reflector Concentrator used as direct generator in a Solar-GAX cycle,” Energy Convers. Manag., vol. 51, no. 3, pp. 434–445, 2010
dc.relation[11] M. Marefati, M. Mehrpooya, and S. A. Mousavi, “Introducing an integrated SOFC, linear Fresnel solar field, Stirling engine and steam turbine combined cooling, heating and power process,” Int. J. Hydrogen Energy, vol. 44, no. 57, pp. 30256–30279, 2019.
dc.relation[12] S. Rita et al., “Promedios mensuales de brillo solar para todas las estaciones de Colombia(horas de sol al dia).”
dc.relation[13] M. y E. A. Ideam(Instituto de Hidrología, “Datos de irradiacion solar en Colombia.”
dc.relation[14] Ideam, “Carácterísticas Climatológicas De Ciudades principales y municipios turisticos de Colombia,” 2015
dc.relation[15] renewables onsite INDUSTRIAL SOLAR, “Technical Data Industrial Solar LF-11 General description.”
dc.relation[16] S. SOLAR, “SCHOTT PTR ® 70 Receiver,” Hattenbergstrasse, Germany
dc.relation[17] C. S. SOLUTIA(Applied Chemistry, “THERMINOL VP-1,” pp. 1–5.
dc.relation[18] J. A. D. Deceased and W. A. Beckman, Solar Engineering of Thermal Processes. University of Wisconsin-Madison.
dc.relation[19] J. D. Nixon and P. A. Davies, “Cost-exergy optimisation of linear Fresnel reflectors,” Sol. Energy, vol. 86, no. 1, pp. 147–156, 2012
dc.relation[20] Y. A. CENGEL, TRANSFERENCIA DE CALOR. University of Nevada, Reno.
dc.relation[21] U. Sahin, “A new non-iterative friction factor correlation for heat transfer fluids in absorber tube of parabolic trough collector,” no. March, 2018.
dc.relation[22] glass made of ideas SCHOTT, “Caracteristicas del vidrio borosilicato templado,” pp. 2–4, 2017
dc.relation[23] Climalife, “Caracteristicas del fluido orgánico R-245fa(PENTAFLUOROPOPANE),” no. 517, 2014.
dc.relation[24] L. GROUP, “Propiedades del R600.”
dc.relation25] A. L. Galindo Noguera, L. S. Mendoza Castellanos, E. E. Silva Lora, and V. R. Melian Cobas, “Optimum design of a hybrid diesel-ORC / photovoltaic system using PSO: Case study for the city of Cujubim, Brazil,” Energy, vol. 142, pp. 33–45, 2018.
dc.relation[26] I. Vaja and A. Gambarotta, “Internal Combustion Engine (ICE) bottoming with Organic Rankine Cycles (ORCs),” Energy, vol. 35, no. 2, pp. 1084–1093, 2010.
dc.relation[27] G. Shu, X. Li, H. Tian, X. Liang, H. Wei, and X. Wang, “Alkanes as working fluids for high-temperature exhaust heat recovery of diesel engine using organic Rankine cycle,” Appl. Energy, vol. 119, pp. 204–217, Apr. 2014.
dc.relation[28] A. Alami Merrouni, A. I. Amrani, H. A. Lahoussine Ouali, M. A. Moussaoui, and A. Mezrhab, “Numerical simulation of Linear Fresnel solar power plants performance under Moroccan climate,” J. Mater. Environ. Sci., vol. 8, no. 12, pp. 4226–4233, 2017.
dc.relation[29] U. Caldiño-herrera, J. C. García, F. Z. Sierra-espinosa, and J. O. Dávalos, “Diseño termodinámico de un ciclo Rankine orgánico para el aprovechamiento energético de aguas termales,” pp. 217–222, 2017.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.titleEstudio de viabilidad técnica de un sistema termo solar con tecnología Fresnel para la producción de electricidad en el Departamento de la Guajira


Este ítem pertenece a la siguiente institución