dc.contributorMantilla Súarez, Juan Carlos [0001482827]
dc.contributorLubinus Badillo, Federico Guillermo [0001475552]
dc.contributorRey Serrano, Juan José [0001475552]
dc.contributorRey Serrano, Juan José [es&oi=ao]
dc.contributorMantilla Suárez, Juan Carlos [0000-0001-8377-9571]
dc.contributorLubinus Badillo, Federico Guillermo [0000-0003-1741-7016]
dc.contributorRey Serrano, Juan José [0000-0002-6946-2444]
dc.contributorRey Serrano, Juan José [54793298100]
dc.contributorGrupo de Investigaciones Clínicas
dc.contributorObservatorio de Salud Pública de Santander
dc.creatorSáenz Prieto, Wilson L
dc.creatorEvan Knepper, Juan David
dc.creatorMantilla Suárez, Juan Carlos
dc.creatorLubinus Badillo, Federico Guillermo
dc.creatorRey Serrano, Juan José
dc.date.accessioned2020-10-27T14:21:15Z
dc.date.available2020-10-27T14:21:15Z
dc.date.created2020-10-27T14:21:15Z
dc.date.issued2007-04-15
dc.identifier2382-4603
dc.identifier0123-7047
dc.identifierhttp://hdl.handle.net/20.500.12749/10358
dc.identifierinstname:Universidad Autónoma de Bucaramanga UNAB
dc.identifierrepourl:https://repository.unab.edu.co
dc.description.abstractResumenObjetivo: Determinar las diferencias en el diagnostico de insuficiencia venosa por ecografÌa doppler color en dos posiciones (semisentado y de pie) utilizando maniobras Valsalva y compresión distal. MetodologÍa: Se estudiaron 98 pacientes con insuÞciencia venosa grado 1 a 3. En todos los pacientes se evaluó la presencia de reßujo estando semisentado más Valsalva, semisentado y compresión distal, de pie más Valsalva, y de pie con compresión distal. Resultados: Hay diferencias en los resultados entre las tÈcnicasevaluadas. Para compromiso proximal hay mayor frecuencia de reßujo en posición semisentado más Valsalva; para compromiso medio las pruebas son similares: para compromiso distal, hay mayor frecuencia de reßujo con el paciente de pie más compresión distal. Conclusión: Dependiendo del grupo venoso a evaluar, es necesario adecuar la técnica de evaluación con ultrasonido doppler color utilizada.[Sáenz WL, Evan JD, Mantilla JC, Lubinus FG, Rey JJ. Variación en el diagnóstico por ecografÍa doppler de insuÞciencia valvular venosa de miembros inferiores, de pie y semisentados utilizando las maniobras de valsalva y compresión distal. MedUNAB 2007; 10:13-18].Palabras clave: Insuficiencia venosa, ecogafÌa doppler color, cirugÍa vascular.
dc.languagespa
dc.publisherUniversidad Autónoma de Bucaramanga UNAB
dc.relationhttps://revistas.unab.edu.co/index.php/medunab/article/view/121
dc.relation1. Giraldo M, Serna J. Fundamentos de medicina. Vascular periférico. Fisiología del sistema venoso. Medellín, CIB, 3 ed, 2001.
dc.relation2. Jantet G. Chronic venous insuffi ciency: worldwide results of the RELIEF study. Refl ux assEssment and quaLity of lIfe improvEment with micronized Flavonoids. Angiology 2002; 53:245-56.
dc.relation3. Nicolaides AN, Cardiovascular Disease Educational and Research Trust, European Society of Vascular Surgery, The International Angiology Scientifi c Activity Congress Organization, International Union of Angiology, Union Internationale de Phlebologie at the Abbaye des Vaux de Cernay. Investigation of chronic venous insuffi ciency: A consensus statement (France, March 5-9, 1997). Circulation 2000; 102:26-63.
dc.relation4. Masuda. EM, Kistner RL, Eklof B. Prospective study of duplex scanning for venous reflux: Comparison of Valsalva and pneumatic cuff techniques in the reverse Trenddelenburg and standing positions. J Vasc Surg 1994; 20:711-20.
dc.relation5. van Bemmelen PS, Bedford G, Beach K, Stranddness DE Jr. Quantitative segmental evaluation of venous valvular refl ux with duplex ultrasound scanning. J Vasc Surg 1989; 10:425-31.
dc.relation6. Foldes MS, Blackburn MC, Holgan J. Standiing versus supine positioning in venous refl ux evaluation. J Vasc Tech 1991; 15:321-4.
dc.relation7. Masuda EM, Kistner RL. Prospective comparison of duplex scanning and descending venography in the assessment of venous insuffi ciency. Am J Surg 1992; 164:254-9.
dc.relation8. Haenen JH, Van Langen H, Janssen MCH, Wollersheim H, van Hot MH, Wim NJC, et al. Venous duplex scanning of the leg: range, variability and reproducibility. Clin Sci 2000; 98:449-54
dc.relation8. Haenen JH, Van Langen H, Janssen MCH, Wollersheim H, van Hot MH, Wim NJC, et al. Venous duplex scanning of the leg: range, variability and reproducibility. Clin Sci 2000; 98:449-54
dc.relation9. Markell A, Heissner M, Manzo R, Bergelin R, Strandness E. A comparison of the cuff defl ation method with Valsalva’s maneuver and limb compression in detecting venous valvular refl ux. Arch Surg 1994; 129:701-5.
dc.relation10. Lagattolla NR, Donald A, Lockhart S, Burnand KG. Retrograde fl ow in the deep veins of subjects with normal venous function. Phlebology 2002; 17:19-28
dc.relation11. Foldes MS, Blackburn MC, Hogan J. Standing versus supine positioning in venous refl ux evaluation. J Vasc Tech 1991; 15:321-4.
dc.relation12. Nash R. Varicose veins. Br Med J 2000; 320:1391-
dc.relation13. Jeanneret KH, Aschwanden L, Bollinger A, Hoffmann U, Jager K. Physiological refl ux and venous diameter change in the proximal lower limb veins during a standardized Valsalva manoeuvre. Permanence J 2003; 7:54-60
dc.relation14. Szendro G, Nicolaides AN, Zukowski AJ, Christopoulos D, Malouf GM, Christodoulou C, et al. Duplex scanning in the assessment of deep venous incompetence. J Vasc Surg 1986; 4:237-42
dc.relation15. Belcaro G, Nicolaides AN, Ricci A, Dugall M, Errichi BM, Vasdekis S, et al. Endovascular sclerotherapy, surgery and surgery plus sclerotherapyin superfi cial venous incompetence: a randomized, 10- year follow up trial –fi nal results. Angiology 2000; 51:529-34
dc.relationhttps://revistas.unab.edu.co/index.php/medunab/article/view/121/107
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.sourceMedUNAB; Vol. 10 Núm. 1 (2007): Sobrepeso, Histeroscopía, Tamizaje de mama; 13-18
dc.subjectCiencias de la salud
dc.subjectMedicina
dc.subjectCiencias médicas
dc.subjectCiencias biomédicas
dc.subjectCiencias de la vida
dc.subjectInnovaciones en salud
dc.subjectInvestigaciones
dc.titleVariación en el diagnóstico por ecografía doppler de insuficiencia valvular venosa de miembros inferiores, de pie y semisentado, utilizando las maniobras de Valsalva y compresión distal


Este ítem pertenece a la siguiente institución