dc.contributorSerpa Vélez, María Fernanda
dc.contributorGutiérrez Villegas, Javier Fernando
dc.creatorArboleda Gaviria, Adriana Miryed
dc.creatorHuertas Valens, Edna Rocio
dc.date.accessioned2020-07-10T19:48:21Z
dc.date.available2020-07-10T19:48:21Z
dc.date.created2020-07-10T19:48:21Z
dc.date.issued2020-07-09
dc.identifierArboleda Gaviria, A. M. y Huertas Valens, E. R. (2020).Cambios superficiales de los sistemas WaveOne Gold® y Reciproc Blue®. Revisión de literatura [Tesis de especialización]. Universidad Santo Tomás, Bucaramanga, Colombia
dc.identifierhttp://hdl.handle.net/11634/27988
dc.identifierreponame:Repositorio Institucional Universidad Santo Tomás
dc.identifierinstname:Universidad Santo Tomás
dc.identifierrepourl:https://repository.usta.edu.co
dc.description.abstractRecently, two Niti instruments with heat treatment and reciprocal motion were introduced on the market: Reciproc Blue (REB) (RPC Blue; VDW, Munich, Germany) and WaveOne Gold (WOG) (Dentsply Tulsa Dental Specialties, Tulsa, OK, U.S. USA). Manufacture and root canal instrumentation cause surface defects in Niti instruments that can be observed through Scanning Electron Microscopy (SEM). The aim of this research is to determine through a literature review, the surface changes associated with torsional and cyclic loads in the Waveone Gold and Reciproc Blue system files, after preparation of artificial canals observed under scanning electron microscopy. Materials and Methods: A literature review was performed, using controlled vocabulary (MESH terms) and natural words related to terms of the problem question on this databases: Pubmed, LILACS, Cochrane, Scopus and Web of Science and the Google Scholar search engine. The search result showed a total of 2249 articles, at the end only 9 articles were fully reviewed. Results: Only 2 of the 9 articles included in this review analyzed the external surface of the instrument. Longitudinal microcracks along the axis and distortion in the machined grooves were founded in both files, when they were subjected to torsional loads. 3 articles evaluated the WOG and REB systems, 4 the WOG system and 2 the REB system. The most recent studies were published in 2019 (n=2), the largest number of articles (n=3) are published in the International Endodontic Journal, classified in Quartil 1 (n=7) and Brazil as affiliation country (n=4). Conclusion: all the 9 included articles, evaluated the fracture pattern through SEM. Only 2 studies observed the external surface of the instrument, finding longitudinal microcracks along the file axis and distortion in the machined grooves in the WOG and REB files under torsional loads. There is no concensus about definition of superficial changes, which limits their analysis. Most of the recently published studies are from Brazil and South Korea, and were published in the International Endodontic Journal (Q1).
dc.languagespa
dc.publisherUniversidad Santo Tomás
dc.publisherEspecialización Endodoncia
dc.publisherFacultad de Odontología
dc.relation1. Nieto C, Mendoza D. Estudio comparativo de los defectos superficiales de las limas Reciproc y Wave One Gold después de la instrumentación de conductos radiculares en molares extraídos mediante el uso de Microscopía Electrónica de Barrido [Tesis].Quito (Ecuador): Universidad San Francisco de Quito; 2017.
dc.relation2. Zupanc J, Vahdat-Pajouh N, Schafer E. New thermomechanically treated NiTi alloys–a review. Int endod J. 2018; 51(10):1088-103. https://doi.org/10.1111/iej.12924
dc.relation3. Plotino G, et al. Experimental evaluation on the influence of autoclave sterilization on the cyclic fatigue of new nickel-titanium rotary instruments. J Endod. 2012; 38(2): 222-5.
dc.relation4. Assayag A, et al. Surface characteristics of reciprocating instruments before and after use–A SEM analysis. Braz Dent J. 2015; 26(2):121-127. https://doi.org/10.1016/j.joen.2011.10.017
dc.relation5. Elsaka S, Elnaghy A, Badr A.Torsional and bending resistance of WaveOne Gold, Reciproc and Twisted File Adaptive instruments. Int Endod J. 2017; 50(11): 1077-83. https://doi.org/10.1111/iej.12728
dc.relation6. Shen Y, Coil J, Mo A, Wang Z, Hieawy A, Yang Y, et al. WaveOne rotary instruments after clinical use. J Endod. 2016; 42(2): 186-9. https://doi.org/10.1016/j.joen.2015.10.008
dc.relation7. Pirani C, Paolucci A, Ruggeri O, Bossù M, Polimeni A, Antonella M, et al. Wear and metallographic analysis of WaveOne and reciproc NiTi instruments before and after three uses in root Canals. Scanning. 2014; 36(5): 517-25. https://doi.org/10.1002/sca.21150
dc.relation8. Alcalde M, Hungaro M, Monteiro C, Carvalho B, Tanomaru-Filho M, Guerreiro J, et al. Cyclic fatigue and torsional strength of three different thermally treated reciprocating nickel-titanium instruments. Clin Oral Investig. 2018; 22(4): 1865-71
dc.relation9. Keskin C, Inan U, Demiral M. Effect of interrupted motion on the cyclic fatigue resistance of reciprocating nickel-titanium instruments. Int Endod J. 2018; 51(5): 549-55. https://doi.org/10.1007/s00784-017-2321-x
dc.relation10. Nogueira E, Monnerat J, Barretto E, Leal V, Moura L, Pereira H. Bending resistance and cyclic fatigue life of a new single-file reciprocating instrument WaveOne Gold. Eur Endod J. 2016; 1(4): 1-4. https:// DOI 10.5152/eej.2016.16018
dc.relation11. Hong J, Sigurdsson A, De-Deus G, Versluis A, Won S, Cheol H. Torsional Behavior of WaveOne Gold Endodontic File with the Dedicated Motor of the Original WaveOne File. Materials (Basel). 2018; 11(7): 1107-1150. https://doi.org/10.3390/ma11071150
dc.relation12. Sobotkiewicz T. Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files [Tesis]. Vancouver (Columbia): The University of British Columbia; 2020. https://dx.doi.org/10.14288/1.0388573
dc.relation13. Ha J, De-Deus G, Versluis A, Kwak S, Kim H. Safe pseudo-elastic limit range under torsional loading with Reciproc Blue. Int Endod J. 2019; 52(2): 244-49. https://doi.org/10.1111/iej.12988
dc.relation14. Mohsen A, Sallam N, Ahmed S. Evaluation of Surface chracteristics changes of WaveOne Gold and WaveOne single reciprocating files using scanning electronmicroscopy: An in-vitro study. JDMT. 2018; 7(1): 25-32.
dc.relation15. Hamdy T, Galal M, Galal A, Abdelraouf R. Evaluation of Flexibility, Microstructure and Elemental Analysis of Some Contemporary Nickel-Titanium Rotary Instruments. Open Access Maced J Med Sci. 2019; 7(21): 3647-54. https://doi.org/10.3889/oamjms.2019.811
dc.relation16. Pedullà E, Maria G, Boninelli S, Rinaldi O, Rapisarda E, Cheol H. Influence of Different Angles of File Access on Cyclic Fatigue Resistance of Reciproc and Reciproc Blue Instruments. J Endod. 2018; 44(12): 1849-55. https://doi.org/10.1016/j.joen.2018.08.012
dc.relation17. Hilfer P, Bergeron B, Mayerchak M, Roberts H, Jeansonne B. Multiple autoclave cycle effects on cyclic fatigue of nickel-titanium rotary files produced by new manufacturing methods. J endod. 2011; 37(1):72-74. https://doi.org/10.1016/j.joen.2010.09.011
dc.relation18. Alapati S, Brantley W, Svec T, Powers J, Mitchell J. Scanning electron microscope observations of new and used nickel-titanium rotary files. J endod. 2003; 29(10):667-669. https://doi.org/10.1097/00004770-200310000-00014
dc.relation19. Faraj R, Capelas J, Vieira M. Effect of repeated use on topographical features of protaper next endodontic rotary file. J Int Or He. 2016; 8(4): 445-450. https/:10.2047/jioh-08-04-07
dc.relation20. Shen Y, Cheung G. Methods and models to study nickel-titanium instruments. Endod Topics. 2013; 29(1): 18-41. https://doi.org/10.1111/etp.12046
dc.relation21. Nogueira E, Leal V, Hecksher F, Silva M, Dos Santos H, Lima E.Cyclic fatigue using severely curved canals and torsional resistance of thermally treated reciprocating instruments. Clin Oral Investig. 2018; 22(7): 2633-8. https:// doi: 10.1007/s00784-018-2362-9.
dc.relation22. Al-Obaida M, Merdad K, Alanazi M, Altwaijry H, Alfaraj M Alkhamis A, et al. Comparison of Cyclic Fatigue Resistance of 5 Heat-treated Nickel-titanium Reciprocating Systems in Canals with Single and Double Curvatures. J Endod. 2019; 45(10): 1237-41. https:// doi: 10.1016/j.joen.2019.06.011.
dc.relation23. Gao Y, Gutmann JL, Wilkinson K, Maxwell R, Ammon D. Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments. J Endod. 2012; 38(3): 398–401. https://doi.org/10.1016/j.joen.2011.11.004
dc.relation24. Shen Y, Zhou H, Zheng Y, Peng B, Haapasalo. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod. 2013; 39(2):163–72. https://doi.org/10.1016/j.joen.2012.11.005
dc.relation25. Zhang E, Cheung G, Zheng Y. A mathematical model for describing the mechanical behaviour of root canal instruments. Int Endod J. 2011; 44(1):72–6. https://doi.org/10.1111/j.1365-2591.2010.01801.x
dc.relation26. Kaval M, Capar I, Ertas H. Evaluation of the cyclic fatigue and torsional resistance of novel nickel-titanium rotary files with various alloy properties. J Endod. 2016; 42(12):1840–3. https://doi.org/10.1016/j.joen.2016.07.015
dc.relation27. Gündoğar M, Özyürek T. Cyclic fatigue resistance of OneShape, HyFlex EDM, WaveOne Gold, and Reciproc blue nickel-titanium instruments. J Endod. 2017; 43(7):1192–6. https://doi.org/10.1016/j.joen.2017.03.009
dc.relation28. Keskin C, Inan U, Demiral M, Keles A. Cyclic Fatigue resistance of Reciproc Blue, Reciproc and WaveOne Gold reciprocanting instruments. J Endod. 2017; 43(8): 1360-3. https://doi.org/10.1016/j.joen.2017.03.036
dc.relation29. De-Deus G, Silva E, Vieira V, Belladona F, Elias C, Plotino G, et al. Blue thermomechanical treatment optimizes fatigue resistance and flexibility of the Reciproc files. J Endod. 2017; 43(3):462–6. https://doi.org/10.1016/j.joen.2016.10.039
dc.relation30. Sattapan B, Nervo G, Palamara J, Messer H. Defects in rotary nickel–titanium files after clinical use. J Endod. 2000; 26(3):161–5. https://doi.org/10.1097/00004770-200003000-00008
dc.relation31. Capar I, Kava M, Ertas H, Hakan B. Comparison of the cyclic fatigue resistance of 5 different rotary pathfinding instruments made of conventional nickel-titanium wire, M-wire and controlled memory wire. J Endod. 2015; 41(4):535–8. https://doi.org/10.1016/j.joen.2014.11.008
dc.relation32. Kim J, Ha J, Cheung G, Versluis A, Wong S, Cheol H. Safety of the factory preset rotation angle of reciprocating instruments. J Endod. 2014; 40(10):1671– 5. https://doi.org/10.1016/j.joen.2014.06.002
dc.relation33. Kim H, Kwak S, Cheung G, Ko D, Chung S, Lee W. Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne. J Endod. 2012; 38(4): 541–4. https://doi.org/10.1016/j.joen.2011.11.014
dc.relation34. Hieawy A, Haapasalo M, Zhou H, Wang Z, Shen Y. Phase transformation behavior and resistance to bending and cyclic fatigue of ProTaper Gold and ProTaper Universal instruments. J Endod. 2015; 41(7):1134–8. https://doi.org/10.1016/j.joen.2015.02.030
dc.relation35. Pedullà E, Lo Savio F, Boninelli S, Plotino G, Grande M, La Rosa G, et al. Torsional and cyclic fatigue resistance of a new nickel-titanium instrument manufactured by electrical discharge machining. J Endod. 2016; 42(1):156-9. https://doi.org/10.1016/j.joen.2015.10.004
dc.relation36. Vasconcelos R, Murphy S, Carvalho C, Govindjee R, Govindjee S, Peters O. Evidence for reduced fatigue resistance of contemporary rotary instruments exposed to body temperature. J Endod. 2016; 42(5):782–7. https://doi.org/10.1016/j.joen.2016.01.025
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.titleCambios superficiales de los sistemas WaveOne Gold® y Reciproc Blue®. Revisión de literatura


Este ítem pertenece a la siguiente institución