dc.contributorOrtiz, Vicky Contanza
dc.contributorGarcía, Mauricio
dc.contributorJimenez, Mauricio
dc.creatorBolívar Barragan, Carlos Andrés
dc.creatorSarmiento Martínez, Sindy Catalina
dc.creatorRodríguez Rojas, Deivid Johan
dc.date.accessioned2019-11-22T15:24:23Z
dc.date.available2019-11-22T15:24:23Z
dc.date.created2019-11-22T15:24:23Z
dc.date.issued2018
dc.identifierBolívar Barragan, C. A. Sarmiento Martínez, S. C. Rodríguez Rojas, D. J. (2018). Conformación de conductos tipo c2 de melton simulados en modelos de resina híbrida con el Sistema mtwo® usando tomografía computarizada de rayo de cono. Trabajo de Especialización]. Universidad Santo Tomás, Bucaramanga, Colombia.
dc.identifierhttp://hdl.handle.net/11634/19979
dc.identifierreponame:Repositorio Institucional Universidad Santo Tomás
dc.identifierinstname:Universidad Santo Tomás
dc.identifierrepourl:https://repository.usta.edu.co
dc.description.abstractis important to assure the complete cleaning, and successful treatment of the root canal. The Cshaped root canal system is an anatomical variation which is generally found in mandibular second molars with a prevalence of 7.6% in mixed racial population. Objective: To determine the efficacy of C shaped canals preparation in simulated hybrid resin models using Mtwo® rotary system. Materials and method: The sample was conformed by twelve hybrid resin models which were located in acrylic blocks with an internal and external morphology of a mandibular second molar with anatomy of a C shaped canal Melton’s Category 2. Cone tomography images were obtained before and after the instrumentation. The simulated canals were instrumented by a single skilled operator, but respecting the technique recommended by the manufacturer. The biomechanical instrumentation was started with K-files ISO 06, 08, 10 and 15, and following with the rotary file ISO 40/4 up to the working length. Results: After applying the descriptive statistics, it was found that coronal wear (11 mm) had a higher value with a mean of 0.3070, with minimum and maximum values of 0.06 to 1.08. Conclusions: The Mtwo@ rotary system was effective when it was used in C-shaped canals as it did not present excessive thinning of the surfaces, and a similar shaping in all root length.
dc.languagespa
dc.publisherUniversidad Santo Tomás
dc.publisherEspecialización Endodoncia
dc.publisherFacultad de Odontología
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.titleConformación de conductos tipo c2 de melton simulados en modelos de resina híbrida con el Sistema mtwo® usando tomografía computarizada de rayo de cono


Este ítem pertenece a la siguiente institución