dc.contributorMorales Avila, Iader Francisco
dc.contributorMesa Gomez, Enrique
dc.creatorMartinez Gonzalez, Carolina
dc.creatorOspina Contreras, Ingrid Catherine
dc.date.accessioned2019-06-07T00:25:04Z
dc.date.available2019-06-07T00:25:04Z
dc.date.created2019-06-07T00:25:04Z
dc.date.issued2019-06-01
dc.identifierMartinez González, C. y Ospina Contreras, I. C. (2019). Comparacion de exactitud y estabilidad dimensional de tres marcas de siliconas de adicion presentes en el mercado Colombiano [Tesis de pregrado]. Universidad Santo Tomás, Bucaramanga, Colombia
dc.identifierhttp://hdl.handle.net/11634/17057
dc.identifierreponame:Repositorio Institucional Universidad Santo Tomás
dc.identifierinstname:Universidad Santo Tomás
dc.identifierrepourl:https://repository.usta.edu.co
dc.description.abstractDifferent printing materials chosen according to the tissues that are needed are used for dental impressions copy and the physical properties of the material, addition silicones haveproved to be more accurate and maintin dimensional stability for dentures taloired to each patients specific oral structures.Assess the accuracy in copying and dimensional stability of three different brands of addition silicones used in the Colombian maket. An in vitro experimental study,where we evaluated 60 models in plaster that resulted from the impression of a master model was designed.With a manual gauge measures the height and width of the pillars and the space between them werw conducted.To determinate the accuracy, measures of the plaster modelwere compared with those of the master model and dimensional stability was evaluated by comparing the measures of the models according to the time of inmmediate emptying at the time,24 hours and one week.The data were processed in the program Stata/MP versión 14.0,ran a univariate analysis were calculated where measures of central tendecy with deviation estándar for each of the measures and the two-way Anova test was performed to evaluate the effect the mark of silicone and emptying time.There were no significant differences between the measures of the models each Brand of silicone and the master model,norbetween the measures of the models at each time of emptying. Three marks evaluated addition silicones have adequate accuracy and stability dimensional, making them optimal for definitivedental impressions and thus obtain satisfactory dentures.
dc.languagespa
dc.publisherUniversidad Santo Tomás
dc.publisherPregrado Odontología
dc.publisherFacultad de Odontología
dc.relation1. Casillas A. Materiales de impresión, características, manipulación e indicaciones. Publicaciones didacticas.19 Noviembre,2011.Páginas 1-6 .
dc.relation2. Ayaviri Pérez R,Bustamante C.Algnato.Rev.Act.Clin.2013.Volúmen 30. Páginas 1-5.
dc.relation3. Naumovski B, Kapushevska B. Dimensional Stability and Accuracy of Silicone – Based Impression Materials Using Different Impression Techniques.prilozi. 2017 Sep 1. Vol38(2).Páginas 131-138.
dc.relation4. Gómez M . Estudio in vitro de la estabilidad dimensional, silicona de adición y polieter en función de la técnica de impresión y el tiempo de vaciad empleados [tesis] Madrid. Universidad Complutense. 2010.
dc.relation5. Hiraguchi H, Kaketani M, Hirose H, Kikuchi H, Yoneyama T. Dimensional changes in stone casts resulting from long-term immersion of addition-type silicone rubber impressions in disinfectant solutions. Dent Mater J. 2013.Vol32(3).Páginas 361–6.
dc.relation6. Vitti R, Oliveira A, Cohelo M. Effect of different impression techniques and elastomeric impression materials on the dimensional accuracy of partially edentulous mandibular arch. Brazilian J Oral Sci. 2016.Vol 15(3).Páginas 238.
dc.relation7. Irene Carmen García Martínez. Estudio experimental comparativo de elastómeros de impresión "digitalizables" vs. "no digitalizables";[tesis] [Madrid] [Universidad Complutense] 2014.
dc.relation8. Dugal R, Railkar B, Musani S. Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. JIOH. 2013 Oct.Vol 5(5).Páginas 85-94.
dc.relation9. Tjan AHL, Li T. Effects of reheating on the accuracy of addition silicone putty-wash impressions. J Prosthet Dent. 1991.Vol65(6).Páginas 743-748.
dc.relation10. Batista F, Fernandes L, Benetti A. Effect of storage period on the accuracy of elastomeric impressions. J Appl Oral Sci.2007 Jun;Vol15(3).Páginas 195-198.
dc.relation11. Anaya S. Modificadores de materiales dentales. Rev. Act. Clin.2013.Vol30.
dc.relation12. Oyanguren Cortijo S,Quintana del Solar M, Morales C.Motivos de repetición de trabajos de un laboratorio dental universitario.Rev Estomatol Herediana.2005.Vol 15 (1).Páginas 40-45.
dc.relation13. Raj P, Sudhia G, Bhat G. Comparative evaluation of dimensional accuracy of addition silicone and condensation silicone impression materials-an invitro study. Dent J Malasyian.2009.Vol 30.Páginas 34-42.
dc.relation14. Wadhwa S, Mehta R, Duggal N, Kumar A, Goel M, Pande S. Influence of Repeat Pours of Addition Silicone Impressions on the Dimensional Accuracy of Casts. J Interdiscipl Med Dent Sc.2014.Vol2(1).
dc.relation15. Diaz R,López E,Veny T.Materiales de impresión en prótesis fija ,criterios para su elección. Cien dent.2007.Vol 4(1).Páginas 71-82.
dc.relation16. Sandra F, Susana B,Oscar F,Miguel Q.Laevolución de las siliconas de adición.Gaceta dental .11 de marzo 2009.
dc.relation17. Chen SY, Chen FN, Liang WM. Factors affecting the accuracy of elastometric impression materials. J Dente 2004 noviembre.Vol 32(8).Páginas 603-609.
dc.relation18. Kumar D, Madihalli AU, Reddy KRK, Rastogi N, Pradeep NT. Elastomeric impression materials: a comparison of accuracy of multiple pours. J Contemp Dent Pract 2011 Jul.Vol 12(4).Páginas 272-278.
dc.relation19. Dugal R, Railkar B, Musani S. Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study. JIOH. 2013 Oct.Vol 5(5).Páginas 85-94.
dc.relation20. 3M Ciencia aplicada [internet]. España. 3M Imprint™ ii vinyl polisiloxano cuerp opesado/liviano Sistema de Material de Impresión. © 3M 2018. 2 de Julio de 2018. Disponible en http://multimedia.3m.com/mws/media/112018O/imprinttm-ii-technical-profile.pdf .
dc.relation21. Zhermack World. [ internet]. España. Elite HD vinylpolysiloxane (a-silicone) impressions material. © 2018 Zhermack SpA – All rights reserved. 2 de Julio de 2018.Disponible en http://www.zhermack.com/public/uploads/EliteHD_IFU-3.pdf .
dc.relation22. Kettenbachusa. [internet].Alemania.Panasil lab putty. © 2016 Kettenbach LP All Rights Reserved. 2 de Julio de 2018. Disponible en http://www.kettenbachusa.com/mdfu/11153.pdf .
dc.relation23. Cho SH, Schaefer O, Thompson G, Guentsch A. Comparison of accuracy and reproducibility of casts made by digital and conventional methods. J Prosthet Dent. 2015;Vol 113(4).Páginas 310-315.
dc.relation24. Cantillo G. Cubetas individuales en prótesis fija, materiales de impresión. [internet]. Corporación universitaria Rafael Nuñez. [2 de julio de 2018].Disponible en https://es.slideshare.net/coldmaster/cubetas-individuales-en-prtesis-fija .
dc.relation25. Kenneth J. Anusavice. Phillips, ciencia de los materiales dentales. Edición 11.Elsevier. 2004.
dc.relation26. Ley 9ª de 1979 en relación con la Red Nacional de Laboratorios y se dictan otras disposiciones. Decreto 2323 de 2006 Julio 12.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/co/
dc.rightsAbierto (Texto Completo)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rightsAtribución-NoComercial-SinDerivadas 2.5 Colombia
dc.titleComparacion de exactitud y estabilidad dimensional de tres marcas de siliconas de adicion presentes en el mercado Colombiano


Este ítem pertenece a la siguiente institución