Fabricación de un Micro Sensor de Presión Implantable Aplicado a Medir Desviaciones Dentro de la Cochlea

dc.creatorPerez, Leonardo
dc.creatorPuers, Robert
dc.creatorVolckaerts, Bart
dc.date.accessioned2019-11-08T21:23:23Z
dc.date.accessioned2022-09-28T11:45:12Z
dc.date.available2019-11-08T21:23:23Z
dc.date.available2022-09-28T11:45:12Z
dc.date.created2019-11-08T21:23:23Z
dc.identifierhttps://repository.unad.edu.co/handle/10596/29649
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3615107
dc.publisherUniversidad Nacional Abierta y a Distancia, UNAD
dc.relationhttp://hemeroteca.unad.edu.co/index.php/publicaciones-e-investigacion/article/view/1102/1265
dc.relation/*ref*/O. Adunka and J. Kiefer. Impact of electrode insertion depth on intracochlear trauma. Journal: Elsevier Inc. Otoralyngology-Head and Neck Surgery. United States: pags 374-382, 2006. [2] P. Roland and W. Gstonttner and O. Adunka. Method for hearing preservation in cochlear implant surgery, Journal: Elsevier Inc. United States: pags 93 - 100, 2005. [3] F. Ceyssens and M. Driesen and R. Puers. An optical absolute pressure sensor for high-temperature applications, fabricated directly on a fiber, Journal: Micromechanics and Microengi- neering. Belgium, 2005. [4] G. Hill and R. Melamud and F. Declerq and A. Davenpoirt and I. Chan and H and B. Pruit SU-8 MEMS Fabry- Perot pressure sensor, Journal: micromechanics and micro- engineering. Vol 13. Pags 52-62 United States, 2007. [5] B. Chen and G. Clark and R. Jones. Evaluation of trayectories and contacts pressures for the straight nucleous cochlear implant electrode array - a two dimensional application of finite element analysis, Elsevier Inc. United states, 2002. [6] J. Roland. A model for cochlear implant insertion and force evaluation: Results with new electrode design and insertion technique, New york University: Laryngoscope. Pag 115. United States, 2005. [7] T. Ran Hsu. MEMS and Microsystems: Design and Manufac- ture, McGraw-Hill: Science/Engineering/Math.1st Ed. 2001. [8] MEMSCYCLOPEDIA, SU8 resist. Thick photo-resistor for MEMS. http://memscyclopedia.org/. [9] J. Hammacker and A. Fuelle and J. Flaemig and J. Saupe and B. Loechele and J. Grim Stress engineering and me- chanical propierties of SU-8 layers for mechanical applications, Microsyst Tech United states, 14:1515-1523. 2008. [10] P. Abgrall and V. Conedera and H. Camon and A. Gue and N. Nguyen SU-8 as a structural material for labson- chips and microelectromechanical systems. Electrophoresis 28. 2007. [11] F. Lindemans and N.F. de Rooij Microsystems technologies for implantable applications. J. Micromech and Microeng 17. R50-R80.2007. [12] J. Lotters and W. Olthuis and P.H. Veltink and P. Bergveld The mechanical propierties of the rubber elasctic polymer poly- dimethylsiloxane for sensor applications. Journal: Microchem and Microeng. Pags 145-147. 1997. [13] A. del Campo and C. Greiner Su-8: a prhotoresistor for high aspect ratio and 3D submicron lithography. Journal: Mi- crochem and Microeng. 2007. [14] N. J. Shirtcliffe and S. Aquil and C. Evans and G. McHale and M.I. Newton and C. Perry and P. Roach The use of high aspect ratio photoresistor (SU-8) for super-hydrophobic pattern prototyping. Journal: Microchem and Microeng. Vol14. Pags 1384-1389. 2004.
dc.rightsCopyright (c) 2015 Publicaciones e Investigación
dc.rightshttp://creativecommons.org/licenses/by-sa/4.0
dc.sourceMagazine specialized in Engineering; Vol. 7 (2013); 11-18
dc.sourcePublicaciones e Investigación; Vol. 7 (2013); 11-18
dc.source2539-4088
dc.source1900-6608
dc.subjectCochlear implant; MEMS sensor; SU8 material; Intra-cochlear trauma
dc.subjectimplante coclear; material SU8 ; sensores MEMS; trauma Intra - coclear
dc.titleFabrication of an Implantable Micro-pressure Sensor to Measure Deviation Within the Cochlea
dc.titleFabricación de un Micro Sensor de Presión Implantable Aplicado a Medir Desviaciones Dentro de la Cochlea
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución