dc.contributorOsorio Bustamante, Edison
dc.creatorRengifo Velásquez, Sebastián
dc.date.accessioned2020-09-03T14:19:25Z
dc.date.available2020-09-03T14:19:25Z
dc.date.created2020-09-03T14:19:25Z
dc.date.issued2019
dc.identifierhttp://hdl.handle.net/1992/43983
dc.identifierinstname:Universidad de los Andes
dc.identifierreponame:Repositorio Institucional Séneca
dc.identifierrepourl:https://repositorio.uniandes.edu.co/
dc.description.abstractDe acuerdo a las recomendaciones normativas actuales, las estructuras de concreto reforzado localizadas en zonas de amenaza sísmica se diseñan para garantizar la seguridad de la vida. Para ello, se incluyen dentro de las estructuras mecanismos con capacidad de disipar energía y una estrategia es establecer unas zonas capaces de incursionar en comportamiento dúctil en el mecanismo de flexión. Sin embargo, la respuesta en un sismo es compleja e intervienen un sin número de variables y que en el diseño se han simplificado para facilitar la ejecución del diseño. En consecuencia, se han desarrollado métodos para verificar el desempeño sísmico de las estructuras y que actualmente son optativos. En ese sentido, este trabajo tiene como objetivo realizar el diseño de una estructura del edificio Altavista dentro de los lineamientos del reglamento NSR-10 con base en un análisis elástico y evaluar su desempeño mediante un análisis no lineal siguiendo las recomendaciones del ASCE 41-17. El sistema estructural de la edificación es un sistema combinado conformado por pórticos resistentes a momento en conjunto con muros estructurales, ambos con capacidad especial de disipación de energía. Para esta estructura, en los resultados de los análisis no lineales se encuentra que la estructura alcanza los objetivos de desempeño establecidos. Sin embargo, se requiere un mayor refuerzo a cortante de los muros estructurales respecto al diseño elástico.
dc.description.abstractAccording to current regulatory recommendations, reinforced concrete structures located in areas of seismic threat are designed to ensure the safety of life. To this end, mechanisms with the capacity to dissipate energy are included within the structures and a strategy is to establish areas capable of entering into ductile behavior in the flexion mechanism. However, the response in an earthquake is complex and a number of variables are involved and that in the design have been simplified to facilitate the execution of the design. Consequently, methods have been developed to verify the seismic performance of the structures and which are currently optional. In this sense, this work aims to design a structure of the Altavista building within the guidelines of the NSR-10 regulation based on an elastic analysis and evaluate its performance through a non-linear analysis following the recommendations of the ASCE 41- 17. The structural system of the building is a combined system consisting of resistant frames at the moment in conjunction with structural walls, both with special capacity for energy dissipation. For this structure, the results of the nonlinear analyzes show that the structure achieves the established performance objectives. However, greater shear reinforcement of the structural walls with respect to the elastic design is required.
dc.languagespa
dc.publisherUniandes
dc.publisherMaestría en Ingeniería Civil
dc.publisherFacultad de Ingeniería
dc.publisherDepartamento de Ingeniería Civil y Ambiental
dc.rightsAl consultar y hacer uso de este recurso, está aceptando las condiciones de uso establecidas por los autores.
dc.rightshttps://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.sourceinstname:Universidad de los Andes
dc.sourcereponame:Repositorio Institucional Séneca
dc.titleDiseño estructural y revisión del comportamiento no lineal del Edifico Altavista ubicado en Santiago de Cali, Valle del Cauca, Colombia
dc.typeTrabajo de grado - Maestría


Este ítem pertenece a la siguiente institución