dc.description.abstractWe report the assembly and testing of a preamplification and amplification system for pulses produced by gaseous radiation detectors commonly used in Mössbauer spectroscopy. The system is composed by a pair of commercial integrated circuits A203 and A206, which operate as charge sensitive preamplifier-shaping amplifier and linear amplifier-low level discriminator, respectively. The integrated circuits were interconnected in the unipolar output mode and placed inside a metallic shielding, which prevents noise amplification for a suitable signal-noise ratio. The system was tested by irradiating a proportional counter LND-45431 with characteristic X rays of 6.3 keV and gamma rays of 14.4 keV emitted by a Mössbauer radioactive source of 57Co (Rh). Unipolar pulses with Gaussian profile were obtained at the output of the linear amplifier, whose amplitudes were close to 0.4 V for 6.3 keV X rays and 1.4 V for 14.4 keV gamma rays. Pulse height spectra showed that the system allows a satisfactory identification of the X-rays and gamma rays emitted by the 57Co source, giving the possibility to make a good selection of the 14.4 keV peak for having a suitable signal-noise ratio in the Mössbauer spectra. Absorption percentages of 14 % were found by taking the Mössbauer spectra of a natural iron absorber. The assembly and tests of the system are presented through this paper. © 2013 Springer Science+Business Media Dordrecht.
dc.languageeng
dc.publisherSPRINGER
dc.relationhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84889254561&doi=10.1007%2fs10751-013-0818-5&partnerID=40&md5=72a114c2e8f15a28953aeb003198bd5d
dc.rightshttps://v2.sherpa.ac.uk/id/publication/issn/0304-3843
dc.sourceHyperfine Interactions
dc.titleImplementation of a preamplifier-amplifier system for radiation detectors used in Mössbauer spectroscopy