Objectives: The aim of this paper was to monitor the presence of SARS-Cov-2 among hospital environment
surfaces, sewage, and personal protective equipment (PPE) of staffs in isolation wards in the First
Affiliated Hospital of Zhejiang University, China.
Methods: Surfaces of objects were routinely wiped with 1000 mg/L chlorine containing disinfectant. Air
and sewage disinfection was proceeded routinely and strictly. Hospital environmental surfaces and PPE
of staffs in isolation wards were sampled using swabs. The sewage from various inlet and outlets were
sampled. The respiratory and stool specimens of patients were collected. The respiratory specimens of
staffs in the isolation wards were also sampled once a week. Quantitative real-time reverse transcription
PCR (qRT-PCR) methods were used to confirm the existence of SARS-Cov-2 RNA. Viral culture was done
for the samples positive for SARS-Cov-2 RNA.
Results: During the study period, 33 laboratory-confirmed patients were hospitalized in isolation wards
in the hospital. None of SARS-Cov-2 RNA was detected among the 36 objects surface samples and 9 staffs
PPE samples in isolation wards. Though the 3 sewage samples from the inlet of preprocessing disinfection
pool were positive for SARS-CoV-2 RNA and the sample from the outlet of preprocessing disinfection pool
was weakly positive, the sewage sample from the outlet of the last disinfection pool was negative. All of
the 5 sewage samples from various points were negative by viral culture of SARS-Cov-2. None of the
respiratory specimens of staffs in the isolation wards were positive.
Conclusions: Though SARS-Cov-2 RNA of the sewage samples were positive from inlets of the sewage
disinfection pool and negative from the outlet of the last sewage disinfection pool, no viable virus was
detected by culture. The monitoring data in this study suggested that the strict disinfection and hand
hygiene could decrease the hospital-associated COVID-19 infection risk of the staffs in isolation wards