dc.contributorVásquez Sarria, Nancy
dc.creatorLarrahondo Chávez, Diego Alejandro
dc.date.accessioned2019-12-12T14:40:55Z
dc.date.accessioned2022-09-22T18:28:50Z
dc.date.available2019-12-12T14:40:55Z
dc.date.available2022-09-22T18:28:50Z
dc.date.created2019-12-12T14:40:55Z
dc.date.issued2019-08-05
dc.identifierhttp://red.uao.edu.co//handle/10614/11707
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3452301
dc.description.abstractWastewater has a high potential for use, because it derives highly utilizable resources such as water, nutrients, sludge and energy. Thus, in this degree work, the potential for the recovery of nitrogen and phosphorus in the form of struvite was evaluated, based on the chemical treatment of wastewater. The project had an experimental stage on a laboratory scale in which conditions necessary to promote struvite precipitation, such as the dose of precipitating reagent (MgCl2) and the reaction pH were evaluated and analyzed, from the treatment of two types of wastewater samples, which corresponded to raw wastewater (ARC) and treated wastewater (ART) from the wastewater treatment plant of the Universidad Autónoma de Occidente. The analysis of the struvite recovery potential showed that from the treatment of 1.0 m3 of ARC it is possible to obtain 62.36 ± 23.21 g of struvite and from the ART 22.57 ± 5.72 g, considering the available phosphorus in wastewater as limiting reagent reaction. From the operational conditions evaluated, it was found that for the tests with pH adjustment of reaction and without external source of magnesium, those that presented a better response in terms of reduction of particulate material, dissolved material, and nutrients, were for a pH of reaction of 11,48 and 11,39 units for the ARC and the ART respectively. For the tests with external source of magnesium and pH adjustment of reaction, it was found that the operational conditions with a better response in terms of reduction of particulate material, dissolved material and nutrients, were for the ARC with a magnesium chloride dose of 131,7 ppm and reaction pH of 9,32 units, and for the ART a dose of 15,9 ppm magnesium chloride and reaction pH of 9,33 units
dc.languagespa
dc.publisherUniversidad Autónoma de Occidente
dc.publisherAdministración Ambiental
dc.publisherDepartamento de Energética y Mecánica
dc.publisherFacultad de Ingeniería
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAtribución-NoComercial-SinDerivadas 4.0 Internacional (CC BY-NC-ND 4.0)
dc.rightsDerechos Reservados - Universidad Autónoma de Occidente
dc.sourceinstname:Universidad Autónoma de Occidente
dc.sourcereponame:Repositorio Institucional UAO
dc.sourceAsociación Española para la Calidad (AEC). (2014). Los Sistemas de Gestión Energética (SGE) [Ebook]. España: Centro Nacional de Información de la Calidad. Recuperado de https://www.aec.es/c/document_library/get_file?uuid=88f8ee2e-2656-4e02-aeaa-d081b96f59bd&groupId=10128 Andersson, E., Arfwidsson, O., Bergstrand, V., & Thollander, P. (2017). A study of the comparability of energy audit program evaluations. Journal of cleaner production, 142, 2133-2139. Basurko, O.C., Gabiña, G., Uriondo, Z., 2013. Energy performance of fishing vessels and potential savings. J. Clean. Prod. 54, 30–40. Bertoldi, P., 2001. Effective Policies and Measures in Energy Efficiency in End-Use Equipment and Industrial processes. In: Proceedings of the 2001 Workshop on Good Practices in Policies and Measurers. López Cardona, J. C. Criterios para la realización de una Auditoría Energética en usuarios Oficiales, Comerciales y Residenciales de Colombia (Doctoral dissertation, Universidad Nacional de Colombia-Sede Manizales). Recuperado de http://bdigital.unal.edu.co/58388/1/1053799930.2017.pdf ClimateWorks Foundation. (2017). Energy Efficiency - ClimateWorks Foundation. Recuperado de https://www.climateworks.org/portfolios/energy-efficiency/ CONSORCIO URECANCOL. (2000). Evaluación expost de las auditorías energéticas en el sector industrial de Colombia [Ebook]. Bogotá: UPME. Retrieved from http://bdigital.upme.gov.co/handle/001/880 Daly, H. E., (1973). Toward a steady-state economy (Vol. 2). San Francisco: WH Freeman. Recuperado de https://is.muni.cz/el/1423/jaro2015/ENS242/um/55677449/3_Daly_2008_Towards_a_Steady_State_Economy.pdf European Commission (EC), 2011. Communication from the Commission. Action Plan for Energy Efficiency: Realising the Potential. COM (2011)545. Recuperado dehttps://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=COM:2011:0109:FIN:EN:PDF Hall, E. (2016). El Manejo de la Energía, más que una Alternativa, una Prioridad para la Gerencia de las Industrias de Hoy. Prisma Tecnológico, 2(1), 28-30. Herrera Ortiz, J. J., y Rengifo Castro, A. (2016). Auditoria energética en el Hotel Intercontinental Cali conforme a los lineamientos de la Norma ISO 50002. Universidad Autónoma de Occidente. Universidad Autónoma de Occidente. Recuperado de http://red.uao.edu.co/handle/10614/8843 International Energy Agency (IEA), 2017. World Energy Outlook 2017. Recuperado de https://www.iea.org/weo2017/ International Energy Agency (IEA), 2018. Energy Efficiency. The global exchange for energy efficiency policies, data and analysis. Recuperado de https://www.iea.org/efficiency2018/ International Organization for Standardization (ISO), 2018. ISO 50001:2018 Energy management systems -- Requirements with guidance for use. Recuperado de https://www.iso.org/standard/51297.html International Organization for Standardization (ISO), 2014. ISO 50002:2014, Energy audits — Requirements with guidance for use. Recuperado de https://www.iso.org/standard/60088.html KfW, 2013. Energy Costs and Energy Efficiency in the German SME Sector. https://www.kfw.de/PDF/Download-Center/Konzernthemen/Research/PDFDokumente- Fokus-Volkswirtschaft/Fokus-englische-Dateien/Fokus-Nr.-40- Dezember-2013-_EN.pdf. Krämer, S., & Engell, S. (2018). Resource Efficiency of Processing Plants (1st ed.). Weinheim: Wiley-VCH Verlag GmbH & Co. KGaA. Meadows, D.H., Meadows, D.L., Randers, J., and Behrens, W.W. III (1972) The Limits of Growth, A Report for the Club of Rome’s Project on the Predicament of Mankind, Universe Books, New York.NRDC, TERI, IGSD, 2018. Improving Air Conditioners in India: Cooling India with Less Warming Series – Affordable and Efficient Room Air Conditioners, assets.nrdc.org/sites/default/files/cooling-india-issue-brief-2018_0.pdf. Ramirez, C.A., Patel, M., Blok, K., 2005. The non-energy intensive manufacturing sector. An energy analysis relating to the Netherlands. Energy 30 (5), 749–767. Rosaura P. Castrillón, José P. Monteagudo, Aníbal Borroto, Enrique Ciro Quispe “Línea de Base Energética en la implementación de la norma ISO 50001. Estudios de casos”. El Hombre y la Máquina No. 46, enero - junio de 2015, pp.137-143. Rosaura P. Castrillón, Enrique Ciro Quispe, Adriana J. Hinestroza, Magdalena Urhan, Diego Fandiño, “Metodología para la implementación del sistema de Gestión Integral de la Energía. Fundamentos y casos prácticos.” Programa editorial Universidad Autónoma de Occidente, Santiago de Cali, pp.278. Schumacher, E. (1973) Small is Beautiful: Economics as if People Mattered, Harper & Row, New York. Shipley, A.M., Elliot, R.E., 2001. Energy efficiency programs for small and medium sized industry. In: Proceedings of the 2001 ACEEE summer study on energy efficiency in industry, vol. 1. American Council for an Energy-Efficient Economy, pp. 183–196. Thollander, P., Danestig, M., & Rohdin, P. (2007). Energy policies for increased industrial energy efficiency: Evaluation of a local energy programme for manufacturing SMEs. Energy policy, 35(11), 5774-5783. Van der Hoeven, M., & Houssin, D. (2015). Energy technology perspectives 2015: mobilising innovation to accelerate climate action. International Energy Agency: Paris, France. Wagner, J. R., Mount, E. M., Giles, H. F., Wagner, J. R., Mount, E. M., & Giles, H. F. (2014). Extrusion Process. Extrusion, 3–11. https://doi.org/10.1016/B978-1-4377-3481-2.00001-6
dc.subjectIngeniería Ambiental
dc.subjectAguas residuales-Análisis
dc.subjectEstruvita
dc.subjectRecuperación de nitrógeno
dc.subjectRecuperación de nutrientes
dc.subjectSewage-Analysis
dc.subjectWastewater
dc.subjectStruvite
dc.titleRecuperación de nutrientes en forma de estruvita a partir del agua residual generada en campus universitarios: caso de estudio Universidad Autónoma de Occidente
dc.typeTrabajo de grado - Pregrado


Este ítem pertenece a la siguiente institución