dc.creatorMerchán Mendoza, Gabriel
dc.creatorMerchán Price, María Susana
dc.creatorMejía Argüello, Jairo Emilio
dc.date.accessioned2019-04-02T22:12:15Z
dc.date.available2019-04-02T22:12:15Z
dc.date.created2019-04-02T22:12:15Z
dc.date.issued2019
dc.identifierMendoza, G. M., Price, M. S. M., & Argüello, J. E. M. (2019). La hipotenusa de Pitágoras como índice de ametropía. Revista Investigaciones Andina (En línea), 21(38).
dc.identifier0124-8146
dc.identifierhttp://revia.areandina.edu.co/ojs/index.php/IA/article/view/992
dc.identifierhttps://digitk.areandina.edu.co/handle/areandina/2779
dc.description.abstractObjetivo General Crear un Índice, con base en la hipotenusa de Pitágoras, para representar cualquier estado refractivo y facilitar los análisis estadísticos de los pacientes amétropes. Métodos 3964 pacientes de una base de datos de OPTILASER (Centro de Cirugía Refractiva en Bogotá, Colombia) del año 2014, fueron seleccionados para demostrar la aplicabilidad del Índice de Ametropía propuesto. Los pacientes no habían sido sometidos a ningún tipo de procedimiento quirúrgico. Otro ejemplo para ilustrar la aplicabilidad del Índice de Ametropía, viene de la investigación “Madre Canguro Integral” llevada a cabo entre 2013 y 2014 en el Hospital de San Ignacio, Bogotá, en la cual 311 bebés nacidos prematuramente y en buen estado de salud, fueron evaluados. Los Meridanos Principales de las ametropías se toman como catetos de un triángulo rectángulo para calcular la Hipotenusa que será tomada como Índice de Ametropía. Seguidamente, se determinó la correlación de Spearman entre el Índice de Ametropía y el Ángulo Visual expresado con Mínimo Angulo de Resolución (MAR). Resultados La correlación de Spearman entre el Índice de Ametropía y el Mínimo Ángulo de Resolución es 0,834 lo cual es estadísticamente significativa (p:< 0,001) y suficiente para validar el Índice propuesto. Conclusiones El Índice de Ametropía es un instrumento válido para la evaluación, manejo y análisis estadístico de las ametropías.
dc.description.abstractGeneral Objective. To create a suitable Index, based on Pythagoras’ hypotenuse, to represent any refractive state and to facilitate statistical analyses of ametropic patients. Methods. 3964 patients from a database of OPTILASER (Refractive Surgery Center in Bogotá, Colombia) for the year 2014 were selected to demonstrate the applicability of the proposed Index of Ametropia. The patients had not been previously subjected to any kind of surgical procedure. Another example to illustrate the applicability of the proposed Index of Refraction comes from a database of an investigation “Madre Canguro Integral” (Integral Kangaroo Mother), carried out between 2013 and 2014 at Hospital San Ignacio, Bogotá in which 311 healthy prematurely-born babies were evaluated Principal meridians of ametropias are taken as catheti of a right triangle in order to calculate the Hypotenuse which will be taken as the Index of Ametropia. Spearman Correlation, between the Index of Ametropia and the Visual Acuity expressed as the Minimum Angle of Resolution (MAR), are determined. Results. Spearman Correlation between the Index of Ametropia and the Minimum Angle of Resolution is 0,834 statistically significant (p: < 0,001) ample enough to validate the proposed Index of Ametropia. Conclusions. The Index of Ametropia is a valid instrument for the
dc.languagees
dc.publisherBogotá: AREANDINA. Fundación Universitaria del Área Andina
dc.rightsBajo la gravedad del juramento, manifiesto que: a) Soy titular de todos los derechos, tanto morales como patrimoniales de autor sobre “la obra” y en consecuencia, cuento con las autorizaciones pertinentes para autorizar cualquier tipo de uso sobre la misma y sobre los derechos que se derivan de la misma, b) Garantizo la originalidad de “la obra”, gozo de la libre disponibilidad de sus derechos, y si he incluido en ella textos, piezas gráficas u otro material de propiedad de terceros, lo he hecho con autorización de dichas personas para reproducirlos en “la obra”, igualmente si “la obra” fue preparada conjuntamente con otros autores, c) No he contraído ni contraeré compromisos, licencias o gravámenes de ninguna especie sobre “la obra”. d) Libero a la Fundación Universitaria del Área Andina, sus funcionarios, trabajadores, contratistas, fundadores y a quienes ésta libremente designe autorizar el uso y/o ceda el derecho de uso sobre “la obra”, de cualquier responsabilidad que emane del ejercicio de los derechos que se derivan de la misma, y de cualquier reclamación que terceras personas respecto de la titularidad o autorizaciones de uso de “la obra”.
dc.subjectíndice de ametropía
dc.subjectmeridianos principales
dc.subjectHipotenusa de Pitágoras
dc.titleLa hipotenusa de Pitágoras como índice de ametropía
dc.typeArticle


Este ítem pertenece a la siguiente institución