dc.creatorPeláez, Alina Noelia
dc.creatorPonce, Alejandro Javier
dc.creatorMazza, Silvia Matilde
dc.date.accessioned2020-06-02T22:34:27Z
dc.date.available2020-06-02T22:34:27Z
dc.date.created2020-06-02T22:34:27Z
dc.date.issued2013-11
dc.identifierPeláez, Alina Noelia, Ponce, Alejandro Javier y Mazza, Silvia Matilde, 2013. Validación de la sonda milimetrada como instrumento de medida del índice estético dental. Odontoestomatología. Montevideo: Universidad de la República Uruguay. Facultad de Odontología, vol. 15, no. 22, p. 16-23. ISSN 1688-9339.
dc.identifier1688-9339
dc.identifierhttp://repositorio.unne.edu.ar/handle/123456789/1668
dc.description.abstractComparar los valores obtenidos con sonda milimetrada y compás de punta seca como instrumentos de medida en la aplicación del Índice Estético Dental (DAI). Metodología: En 50 pacientes mayores de 12 años con dentición permanente, del Hospital Odontológico de la Facultad de Odontología de la Universidad Nacional del Nordeste (UNNE), se midieron las variables que componen el DAI, alternando ambos instrumentos de medición y se calculó el DAI. Resultados: En un 86 % de los casos ambos instrumentos arrojaron valores idénticos para las variables del DAI y en el 14 % restante las variaciones no superaron el mm. La correlación entre la puntuación final del DAI, midiendo las variables con sonda milimetrada y con compás de punta seca, fue estadísticamente significativa (r= 0,999). Conclusión: Las variaciones entre las medidas no influyeron en la puntuación final del índice lo que valida a la sonda milimetrada como instrumento de registro para el cálculo del DAI.
dc.description.abstractCompare the values obtained with calibrated probe and with drypoint compass as measuring instrument in implementing the Dental Aesthetic Index (DAI). Methodology: In 50 patients over 12 years with permanent dentition from ofDental Hospital, Faculty of Dentistry UNNE,were measured the variables that built the DAI, alternating both measuring instruments and estimated the DAI. Results: In 86% of cases both instruments yielded identical values for the DAI variables and the remaining 14% did not exceed one mm. The correlation between the final score of the DAI, measuring variables with calibrated probe and drypoint compass, was statistically significant (r = 0.999). Conclusions: Variations between measures not influence the final score of the indexvalidates the calibrated probe as a tool of registration for calculating the DAI.
dc.languagespa
dc.publisherUniversidad de la República de Uruguay. Facultad de Odontología
dc.relationhttp://www.scielo.edu.uy/pdf/ode/v15n22/v15n22a03.pdf
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.rightsopenAccess
dc.sourceOdontoestomatología, 2013, vol. 15, no. 22 p. 16-23.
dc.subjectMaloclusión
dc.subjectEstética dental
dc.subjectOrtodoncia correctiva
dc.subjectInstrumentos dentales
dc.subjectMalocclusion
dc.subjectAesthetics-dental
dc.subjectCorrective orthodontics
dc.subjectDental instruments
dc.titleValidación de la sonda milimetrada como instrumento de medida del índice estético dental