dc.contributor | Aguiar, Mônica Lopes | |
dc.contributor | http://lattes.cnpq.br/0431688649128529 | |
dc.contributor | http://lattes.cnpq.br/1536476217054773 | |
dc.creator | Oliveira, Flávia Matias | |
dc.date.accessioned | 2016-10-04T17:30:37Z | |
dc.date.available | 2016-10-04T17:30:37Z | |
dc.date.created | 2016-10-04T17:30:37Z | |
dc.date.issued | 2015-04-30 | |
dc.identifier | OLIVEIRA, Flávia Matias. Estudo do efeito eletrostático na filtração de partículas de cimento em filtros de mangas. 2015. Dissertação (Mestrado em Engenharia Química) – Universidade Federal de São Carlos, São Carlos, 2015. Disponível em: https://repositorio.ufscar.br/handle/ufscar/7615. | |
dc.identifier | https://repositorio.ufscar.br/handle/ufscar/7615 | |
dc.description.abstract | Nowadays the control of industrial pollution is essential. Through filtering, you can remove
the suspended solids in gases. It has been need for more efficient methods for gas filtration in
order to reduce waste generation and decrease energy consumption. In this study was
proposed to investigate the behavior of the particulate matter, cement and the influence of
particle size in formation of gas dust cake, with and without eletrostatic charged. The filter in
order to determine aspects were analyzed and compare their characteristics after filtration,
defining which one operationally more suitable for this process. In this investigation the study
aims optimize the filtration operation. In order to obtain a greater retention of particulates. In
this sense, fabric filter were analyzed, glass and polypropylene filter, while gas filtration.
Cement was used as particulate material with grain sizes 8, 14 and 20μm, the corona
chargering was added in the filtration of gas during the formation of dust cake. The tests were conduction in an attempt to understand this effect the electrostatic charge, improve and
increase the service life of the filter media. Was necessary to adapt it to the equipment one
system gas filtration, localized in Department of Chemical Engineering (DEQ) of Federal
University of São Carlos (UFSCar), for receive the corona charged. The experiment was
conducted from voltage of 0 to -2 kV test with a filtration rate of 10 cm/s, and the mass flow
of 9 mg/s. With the tests done, it possible show that, with the application the corona
chargering the dust cake changes. It can be that the particle size directly affects the filtration
efficiency and the load, can increase the efficiency the collect to particulate and decrease pressure drop during filtration of gases. | |
dc.language | por | |
dc.publisher | Universidade Federal de São Carlos | |
dc.publisher | UFSCar | |
dc.publisher | Programa de Pós-Graduação em Engenharia Química - PPGEQ | |
dc.publisher | Câmpus São Carlos | |
dc.rights | Acesso aberto | |
dc.subject | Filtração de gases | |
dc.subject | Carregador corona | |
dc.subject | Material particulado | |
dc.subject | Cimento | |
dc.subject | Filtros de manga | |
dc.subject | Corona Charger | |
dc.subject | Filtration | |
dc.subject | Particulate matter | |
dc.subject | Cement and Bag Filter | |
dc.title | Estudo do efeito eletrostático na filtração de partículas de cimento em filtros de mangas | |
dc.type | Tesis | |