dc.contributor | Correal Daza, Juan Francisco Javier | |
dc.contributor | Reyes Ortiz, Juan Carlos | |
dc.contributor | Ramírez Rodríguez, Fernando | |
dc.contributor | Yamín Lacouture, Luis Eduardo | |
dc.creator | Durán Coy, Alexander | |
dc.date.accessioned | 2018-09-28T10:31:30Z | |
dc.date.available | 2018-09-28T10:31:30Z | |
dc.date.created | 2018-09-28T10:31:30Z | |
dc.date.issued | 2015 | |
dc.identifier | http://hdl.handle.net/1992/13258 | |
dc.identifier | instname:Universidad de los Andes | |
dc.identifier | reponame:Repositorio Institucional Séneca | |
dc.identifier | repourl:https://repositorio.uniandes.edu.co/ | |
dc.description.abstract | En el presente trabajo se realiza la evaluación del comportamiento no lineal estático de un edificio de 10 pisos cuyo sistema estructural es "Pórticos de concreto reforzado resistentes a momentos" con "capacidad de disipación especial de energía" localizado en Bucaramanga (zona de amenaza sísmica alta) cuyo diseño se realizó a la luz de la norma NSR-10. Esta evaluación se realiza a la luz de los requisitos del estándar ASCE 41-13 (Rehabilitación sísmica de edificios existentes), mediante el cual se puede establecer un nivel de comportamiento de la estructura para el sismo de diseño, y a su vez permite verificar el desempeño del edificio. Se presenta memorias de diseño y planos de construcción, de acuerdo con las prácticas profesionales para este tipo de proyectos. | |
dc.description.abstract | In this paper the evaluation of nonlinear elastic behavior of a 10-story building is carried whose structural system is "Resistant Reinforced Concrete Frames" with "special capacity to energy dissipation" located in Bucaramanga (high seismic hazard zone) whose design is made with NSR-IO parameters. This evaluation is done with the requirements of the standard ASCE 41-13 (seismic rehabilitation of existing buildings), through which is possible set a standard of behavior of the structure for the design earthquake, and at the same time is possible verifies the performance of the building. Memories of design and construction drawings, according to professional practices for such projects is presented. | |
dc.language | spa | |
dc.publisher | Uniandes | |
dc.publisher | Maestría en Ingeniería Civil | |
dc.publisher | Facultad de Ingeniería | |
dc.publisher | Departamento de Ingeniería Civil y Ambiental | |
dc.rights | Al consultar y hacer uso de este recurso, está aceptando las condiciones de uso establecidas por los autores. | |
dc.rights | https://repositorio.uniandes.edu.co/static/pdf/aceptacion_uso_es.pdf | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.rights | http://purl.org/coar/access_right/c_abf2 | |
dc.source | instname:Universidad de los Andes | |
dc.source | reponame:Repositorio Institucional Séneca | |
dc.title | Análisis no lineal estático de un edificio de 10 pisos ubicado en Bucaramanga | |
dc.type | Trabajo de grado - Maestría | |