dc.contributorFGV
dc.creatorCamargo, Sabrina
dc.creatorRiedl, Maik
dc.creatorAnteneodo, Celia
dc.creatorKurths, Juergen
dc.creatorPenzel, Thomas
dc.creatorWessel, Niels
dc.date.accessioned2018-05-10T13:36:37Z
dc.date.accessioned2019-05-22T14:26:07Z
dc.date.available2018-05-10T13:36:37Z
dc.date.available2019-05-22T14:26:07Z
dc.date.created2018-05-10T13:36:37Z
dc.date.issued2014-09-15
dc.identifier0959-6526 / 1879-1786
dc.identifierhttp://hdl.handle.net/10438/23412
dc.identifier10.1371/journal.pone.0107581
dc.identifier000341774800085
dc.identifierAnteneodo, Celia/0000-0001-9130-2933; Camargo, Sabrina/0000-0002-0237-3535; Penzel, Thomas/0000-0002-4304-0112
dc.identifierAnteneodo, Celia/C-7179-2013; Camargo, Sabrina/J-3745-2013; Penzel, Thomas/M-2344-2014
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/2694035
dc.description.abstractSleep disorders are a major risk factor for cardiovascular diseases. Sleep apnea is the most common sleep disturbance and its detection relies on a polysomnography, i.e., a combination of several medical examinations performed during a monitored sleep night. In order to detect occurrences of sleep apnea without the need of combined recordings, we focus our efforts on extracting a quantifier related to the events of sleep apnea from a cardiovascular time series, namely systolic blood pressure (SBP). Physiologic time series are generally highly nonstationary and entrap the application of conventional tools that require a stationary condition. In our study, data nonstationarities are uncovered by a segmentation procedure which splits the signal into stationary patches, providing local quantities such as mean and variance of the SBP signal in each stationary patch, as well as its duration L. We analysed the data of 26 apneic diagnosed individuals, divided into hypertensive and normotensive groups, and compared the results with those of a control group. From the segmentation procedure, we identified that the average duration [L], as well as the average variance [sigma(2)], are correlated to the apnea-hypoapnea index (AHI), previously obtained by polysomnographic exams. Moreover, our results unveil an oscillatory pattern in apneic subjects, whose amplitude S* is also correlated with AHI. All these quantities allow to separate apneic individuals, with an accuracy of at least 79%. Therefore, they provide alternative criteria to detect sleep apnea based on a single time series, the systolic blood pressure.
dc.languageeng
dc.publisherPublic Library Science
dc.relationPlos one
dc.rightsopenAccess
dc.sourceWeb of Science
dc.subjectHeart-rate-variability
dc.subjectElectrocardiogram
dc.subjectDesordens do sono
dc.titleSleep apnea-hypopnea quantification by cardiovascular data analysis
dc.typeArticle (Journal/Review)