dc.contributorUniversity Camilo Castelo Branco, UCCB and Foundation Education of Fernandópolis, FEF - Fernandópolis
dc.contributorSão José do Rio Preto Medical School, FAMERP
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorCamilo Castelo Branco University
dc.contributorUniversity Camilo Castelo Branco and Education Foundation of Fernandópolis
dc.contributorCamilo Castelo Branco University, and Education Foundation of Fernandópolis
dc.contributorAnhembi Morumbi University
dc.date.accessioned2018-12-11T17:25:51Z
dc.date.available2018-12-11T17:25:51Z
dc.date.created2018-12-11T17:25:51Z
dc.date.issued2015-01-01
dc.identifierInternational Journal of Morphology, v. 33, n. 3, p. 1002-1008, 2015.
dc.identifier0717-9502
dc.identifier0717-9367
dc.identifierhttp://hdl.handle.net/11449/177526
dc.identifier10.4067/S0717-95022015000300031
dc.identifier2-s2.0-84943389510
dc.description.abstractThere is a great variety of injuries that affect peripheral nerves derived from acquired or congenital degenerative diseases affecting the central nervous system that cause loss of sensorimotor functions. The objective of this work was to perform an endto- side or side-to-side experimental axonal stereological study in order to compare volume density of axons, endouneuro and myelin sheath (and muscle mass) in peroneal and tibial nerves, with anastomosis contact from 0.25 cm to 0.50 cm. After approval of the Ethics Committe, 20 male Wistar rats were divided into four groups of five rats each (G1= end-to-side neurorrhaphy; G2= side-to-side neurorrhaphy of 0.25 cm; G3= side-to-side neurorrhaphy of 0 cm and G4= Control of normality). After 180 days, fragments of peroneal and tibial nerves were collected for histological and stereological study. In comparative stereological experimental study between neurorraphies, the volume density of axons, myelin sheath of tibial and fibular nerves, as well as the post-surgical muscle mass, remains the same in end-to-side and side-to-side neurorraphies, regardless of contact area of anastomosis. It can be inferred, as surgical repair options, both end-to-side neurorrhaphy to recover and prevents atrophy of the endplate as side-to-side neurorraphy that is independent of the distance between the nerve stumps.
dc.languageeng
dc.relationInternational Journal of Morphology
dc.relation0,207
dc.relation0,207
dc.rightsAcesso restrito
dc.sourceScopus
dc.subjectAxon
dc.subjectEndoneurium
dc.subjectMyelin sheath
dc.subjectNeurorraphy
dc.subjectReinnervation
dc.subjectStereolog0y
dc.titleTécnicas de Neurorrafia: Estudio Experimental Estereológico Axonal Comparativo
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución