dc.contributorUniversidade Federal de São Carlos (UFSCar)
dc.contributorUniversidade de São Paulo (USP)
dc.contributorBarueri
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T17:11:16Z
dc.date.available2018-12-11T17:11:16Z
dc.date.created2018-12-11T17:11:16Z
dc.date.issued2017-03-24
dc.identifierAnalytical Letters, v. 50, n. 5, p. 842-852, 2017.
dc.identifier1532-236X
dc.identifier0003-2719
dc.identifierhttp://hdl.handle.net/11449/174473
dc.identifier10.1080/00032719.2016.1195839
dc.identifier2-s2.0-85017546906
dc.identifier2-s2.0-85017546906.pdf
dc.description.abstractA procedure for the determination of As, Cd, Cr, Ni, Pb, and V in phytotherapy medicines by inductively coupled plasma–tandem mass spectrometry is reported. The use of tandem mass spectrometry with oxygen into an octopole reaction system at various gas flow rates and the combination of on-mass and mass-shift modes was evaluated. Cadmium, Cr, Ni, and Pb were determined as free atomic ions while As and V were determined as the oxides AsO+ and VO+ in the same run. Samples were prepared by microwave-assisted digestion with dilute nitric acid and hydrogen peroxide. Two plant-certified reference materials (apple leaves and tomato leaves) were used to check the accuracy. For tandem mass spectrometry with 0.5 mL min−1 O2, recoveries in the 85–113% were typically obtained and no statistical differences were observed at the 95% confidence level (t-test) in comparison with the certified values. Using these conditions, the limits of detection for the method were 0.01, 0.0002, 0.008, 0.008, 0.003, and 0.002 µg g−1 for As, Cd, Cr, Ni, Pb, and V, respectively. The procedure was used for the analysis of four phytotherapic drugs and the determined concentrations were up to 0.168 µg g−1 As, 0.03 µg g−1 Cd, 0.82 µg g−1 Cr, 1.18 µg g−1 Ni, 0.52 µg g−1 Pb, and 2.4 µg g−1 V with average precision values of 8% as the relative standard deviation. The found concentrations were compared with limits proposed in official guidelines and, in most cases, the values were below the maximum limits allowed.
dc.languageeng
dc.relationAnalytical Letters
dc.relation0,344
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectContaminants, elemental impurity determination
dc.subjectICP-MS/MS
dc.subjectinductively coupled plasma–tandem mass spectrometry
dc.subjectphytotherapy medicines
dc.subjectspectral interferences
dc.subjecttrace analysis
dc.titleElemental Analysis of Phytotherapeutic Products by Inductively Coupled Plasma–Tandem Mass Spectrometry
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución