dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal do Mato Grosso - Campus Sinop
dc.contributorBrazilian Army
dc.date.accessioned2018-12-11T17:09:46Z
dc.date.available2018-12-11T17:09:46Z
dc.date.created2018-12-11T17:09:46Z
dc.date.issued2016-01-01
dc.identifierComparative Exercise Physiology, v. 12, n. 2, p. 75-82, 2016.
dc.identifier1755-2559
dc.identifier1755-2540
dc.identifierhttp://hdl.handle.net/11449/174193
dc.identifier10.3920/CEP160002
dc.identifier2-s2.0-85012084028
dc.description.abstractLittle information is available comparing the i-STAT and the YSI 2300 Stat Plus devices to determine the lactate concentration [Lac] in dogs undergoing intense exercise. The reproducibility of the YSI 2300 for quantifying the [Lac] in canine blood [Lac]b and plasma [Lac]p samples has been observed. In addition, the i-STAT handheld device was used to quantify [Lac] in dogs subjected to exercise, and the results were compared with that of YSI 2300. Venous blood samples of Beagle and American Pit Bull Terrier dogs were obtained during an intense exercise training on a treadmill. [Lac]p and [Lac]b were quantified using the YSI 2300 instrument to determine the reproducibility of the results. A total of 52 specimens were compared for both plasma and whole blood. For comparing the devices (YSI 2300 vs i-STAT), 96 samples were used. Ordinary least products regression, the correlation coefficient, and Bland- Altman plots were used to assess the agreement of using the i-STAT device. The relationship between duplicate measurements of both [Lac]b and [Lac]p by YSI 2300 was strong (r=0.99). A correlation between the data obtained using the i-STAT and YSI 2300 instruments was observed for both the [Lac]p (r=0.97) and [Lac]b (r=0.88). The i-STAT exhibited a small constant bias (-0.25 mmol/l) compared to YSI 2300 ([Lac]b). There were proportional biases of 0.89 mmol/l for [Lac]p and 1.22 mmol/l for [Lac]b when using YSI 2300 vs i-STAT. We confirmed the reproducibility of the YSI 2300 for canine lactate blood/plasma samples. The results obtained by the i-STAT and YSI 2300 analyser were highly correlated, but a small constant bias was observed between them. The i-STAT device can be used in clinical evaluations, and it is also adequate for designing and monitoring fitness programmes.
dc.languageeng
dc.relationComparative Exercise Physiology
dc.relation0,212
dc.relation0,212
dc.rightsAcesso restrito
dc.sourceScopus
dc.subjectAmerican Pit Bull Terrier
dc.subjectBeagle
dc.subjectExercise physiology
dc.subjectLeast products regression analysis
dc.subjectPortable blood analyser
dc.subjectVeterinary
dc.titleAgreement between i-STAT and YSI 2300 devices to determine lactate concentrations in dogs undergoing exercise
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución