dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorFederal University of Alfenas–UNIFAL-MG
dc.date.accessioned2018-12-11T17:04:13Z
dc.date.available2018-12-11T17:04:13Z
dc.date.created2018-12-11T17:04:13Z
dc.date.issued2017-01-25
dc.identifierComputer Methods in Biomechanics and Biomedical Engineering, v. 20, n. 2, p. 193-200, 2017.
dc.identifier1476-8259
dc.identifier1025-5842
dc.identifierhttp://hdl.handle.net/11449/173229
dc.identifier10.1080/10255842.2016.1209188
dc.identifier2-s2.0-84978511479
dc.identifier2-s2.0-84978511479.pdf
dc.description.abstractThe aim of study was to evaluate the stress distribution in implant-supported prostheses and peri-implant bone using internal hexagon (IH) implants in the premaxillary area, varying surgical techniques (conventional, bicortical and bicortical in association with nasal floor elevation), and loading directions (0°, 30° and 60°) by three-dimensional (3D) finite element analysis. Three models were designed with Invesalius, Rhinoceros 3D and Solidworks software. Each model contained a bone block of the premaxillary area including an implant (IH, Ø4 × 10 mm) supporting a metal-ceramic crown. 178 N was applied in different inclinations (0°, 30°, 60°). The results were analyzed by von Mises, maximum principal stress, microstrain and displacement maps including ANOVA statistical test for some situations. Von Mises maps of implant, screws and abutment showed increase of stress concentration as increased loading inclination. Bicortical techniques showed reduction in implant apical area and in the head of fixation screws. Bicortical techniques showed slight increase stress in cortical bone in the maximum principal stress and microstrain maps under 60° loading. No differences in bone tissue regarding surgical techniques were observed. As conclusion, non-axial loads increased stress concentration in all maps. Bicortical techniques showed lower stress for implant and screw; however, there was slightly higher stress on cortical bone only under loads of higher inclinations (60°).
dc.languageeng
dc.relationComputer Methods in Biomechanics and Biomedical Engineering
dc.relation0,579
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectbiomechanics
dc.subjectDental implants
dc.subjectfinite element analysis
dc.subjectstress distribution
dc.titleInfluence of bicortical techniques in internal connection placed in premaxillary area by 3D finite element analysis
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución