Artículos de revistas
Determination of Ethambutol in Aqueous Medium Using an Inexpensive Gold Microelectrode Array as Amperometric Sensor
Fecha
2016-05-01Registro en:
Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 28, n. 5, p. 985-989, 2016.
1040-0397
10.1002/elan.201500600
WOS:000379040500010
Autor
Univ Estadual Piaui
Universidade Estadual Paulista (Unesp)
Institución
Resumen
In this paper, gold microelectrode array (Au-MEA) were employed to determination of ethambutol in aqueous medium. Au-MEA was constructed with an electronic microchip integrated circuit. The standard curve (analytical curve) was constructed for a single microelectrode (ME) in a concentration range of 5.0 x 10(-5) to 2.0 x 10(-3) molL(-1), allowing estimation of both the limit of detection (LOD) (4.73 x 10(-5) molL(-1)) and the limit of quantification (LOQ) (1.57 x 10(-4) molL(-1)) for ethambutol. When the MEA was utilized, the LOD and LOQ were 1.55 x 10(-7) and 5.18 x 10(-7) molL(-1), respectively. Our results indicated that Au-MEA can be utilized as amperometric sensors for ethambutol determination in aqueous