dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-11-26T17:52:02Z
dc.date.available2018-11-26T17:52:02Z
dc.date.created2018-11-26T17:52:02Z
dc.date.issued2015-12-01
dc.identifierEuropean Journal Of Prosthodontics And Restorative Dentistry. Lowestoft: Dennis Barber Ltd, v. 23, n. 4, p. 193-198, 2015.
dc.identifier0965-7452
dc.identifierhttp://hdl.handle.net/11449/164299
dc.identifier10.1922/EJPRD_1343Goiato06
dc.identifierWOS:000434933600005
dc.identifier9719883814872582
dc.description.abstractObjectives: The aim of this study was to assess the flexural strength of two brands of thermopolymerisable acrylic resins (Onda Cryl, Artigos Odontologicos Classico Ltda, Sao Paulo, SP, Brazil; and Lucitone 550, Dentsply, York, PA USA) with varying concentrations of pigment (Poli-Cor, Artigos Odontologicos Classico Ltda, Sao Paulo,SP, Brazil) under the influence of thermocycling, storage and disinfection. Material and Methods: A total of 210 samples were manufactured (105 for each acrylic resin brand), with dimensions of 64 x 10 x 3.3 mm. The samples were divided into 30 subgroups (n=7) according to the proportion of pigment used (without pigment, 3% and 7%), the assessment period (initial or thermocycling for 2000 cycles) and disinfection method (immersion in 1% sodium hypochlorite, (Apothicario, Aracatuba, SP Brazil), microwave energy or immersion in alkaline peroxide (Efferdent, Pfizer, Morris Plains, NJ, USA). The samples were submitted to the flexural strength test before and after thermocycling, and after storage with disinfection. The disinfection process was performed every 3 days, for 60 days. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<0.05). Results: The factors that provided statistical alteration in flexural strength values were resin type and assessment period. The Onda Cryl resin and the period after disinfection (126 +/- 25 MPa) exhibited the higher values of flexural strength. Conclusion: Following disinfection, Onda-Cryl resin exhibited the highest values of flexural strength. All the samples obtained are considered clinically acceptable.
dc.languageeng
dc.publisherDennis Barber Ltd
dc.relationEuropean Journal Of Prosthodontics And Restorative Dentistry
dc.relation0,265
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectAcrylic Resins
dc.subjectColor Stability
dc.subjectFlexural Strength
dc.titleThe Effect of Disinfection Techniques on the Flexural Strength of Thermopolymerisable Acrylic Resins With or Without Pigment Addition
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución