dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-11-26T16:05:14Z
dc.date.available2018-11-26T16:05:14Z
dc.date.created2018-11-26T16:05:14Z
dc.date.issued2015-07-01
dc.identifierJournal Of Engineering Science And Technology. Selangor: Taylors Univ Sdn Bhd, v. 10, n. 7, p. 841-848, 2015.
dc.identifier1823-4690
dc.identifierhttp://hdl.handle.net/11449/160605
dc.identifierWOS:000214309200002
dc.description.abstractIn this study, it was investigated the influence of electrolyte concentration and anodizing time on the electrochemical behaviour and morphology of anodic films formed on commercially pure Ti. Electrochemical methods and surface analyses were used to characterize the films. It was found that the electrolyte concentration and anodizing time affect the growth and protective characteristics of films in a physiologic medium. It was possible to observe their non-uniformity on Ti substrates under the tested conditions. In potentiodynamic profiles, it was observed that passivation current values are affected by an anodizing time increase. Variations in impedance spectra were associated with an increase of defects within the film.
dc.languageeng
dc.publisherTaylors Univ Sdn Bhd
dc.relationJournal Of Engineering Science And Technology
dc.relation0,193
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectTitanium
dc.subjectAnodizing
dc.subjectAnodic films
dc.subjectChloride medium
dc.subjectBiomedical implants
dc.titleEFFECT OF PHOSPHORIC ACID CONCENTRATION AND ANODIZING TIME ON THE PROPERTIES OF ANODIC FILMS ON TITANIUM
dc.typeArtículos de revistas