dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-08-06T16:12:57Z
dc.date.available2015-08-06T16:12:57Z
dc.date.created2015-08-06T16:12:57Z
dc.date.issued2014
dc.identifierClinical Oral Investigations, v. 19, n. 3, p. 673–680, 2014.
dc.identifier1436-3771
dc.identifierhttp://hdl.handle.net/11449/125726
dc.identifier10.1007/s00784-014-1285-3
dc.identifier4517484241515548
dc.identifier0493479801083622
dc.identifier0000-0002-4100-5153
dc.description.abstractObjectives This study evaluated the color alteration, cytotoxicity, and hydrogen peroxide (HP) diffusion associated with different in-office bleaching protocols. Materials and methods Bovine enamel/dentin disks were subjected to three bleaching sessions with 35 % HP (three 15-min applications), 35 % HP (one 45-min application), or 20 % HP (one 45-min application). The control group was not bleached. Before bleaching, the disks were adapted to artificial pulp chambers positioned in compartments containing 1 ml of acetate buffer or medium, so that the dentin remained in contact with these substances. Immediately after bleaching, the HP that diffused through the disks was stabilized by acetate buffer and was quantified (two-way repeated measures ANOVA/Fisher’s protected least significant difference (PLSD) test; α=5 %). Cells of mouse dental papilla cell-23 (MDPC-23) were incubated in this culture media for 1 h, followed by analysis of cellular metabolism (methyl tetrazolium assay) (one-way ANOVA/Tukey test; α=5 %) and morphology (scanning electron microscopy). The specimen color alteration (ΔE) was analyzed by reflection spectrophotometry (two-way repeated measures ANOVA/Fisher’s PLSD test; α=5 %). Results All protocols showed equal effectiveness at the end of the treatment. HP diffusion was significantly higher in the groups bleached with 35 % HP. Reapplication of 35 % HP resulted in increased diffusion only in the first session; however, the decrease in cell metabolism was similar for all studied protocols. Conclusion Despite greater peroxide diffusion in the groups treated with 35 % HP, all protocols showed the same effectiveness and were cytotoxic to MDPC-23 cells. Clinical relevance Bleaching protocols using high HP concentrations should be avoided because they exert aggressive actions on odontoblast-like cells.
dc.languageeng
dc.relationClinical Oral Investigations
dc.relation0,986
dc.rightsAcesso restrito
dc.sourceCurrículo Lattes
dc.subjectCytotoxicity
dc.subjectHydrogen peroxide
dc.subjectBleaching agent
dc.subjectCell culture
dc.titleColor alteration, hydrogen peroxide diffusion, and cytotoxicity caused by in-office bleaching protocols
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución