dc.contributorGoiato, Marcelo Coelho [UNESP]
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-06-11T19:35:03Z
dc.date.available2014-06-11T19:35:03Z
dc.date.created2014-06-11T19:35:03Z
dc.date.issued2008-12-19
dc.identifierMANCUSO, Daniela Nardi. O uso da termociclagem na avaliação da absorção, solubilidade, dureza e alteração de cor de reembasadores resilientes. 2008. 48 f. Tese (doutorado) - Universidade Estadual Paulista, Faculdade de Odontologia de Araçatuba, 2008.
dc.identifierhttp://hdl.handle.net/11449/105575
dc.identifier000589187
dc.identifiermancuso_dn_dr_araca.pdf
dc.identifier33004021011P0
dc.identifier9719883814872582
dc.description.abstractEste estudo teve como objetivo avaliar a absorção, solubilidade, dureza e alteração de cor de reembasadores resilientes após termociclagem. Foram utilizados 4 materiais reembasadores resilientes, sendo 1 à base de resina (Trusoft) e 3 à base de silicone (Dentusil, Ufi Gel P e Ufi Gel SC). Foram confeccionadas 80 amostras no total, sendo que metade delas foi submetida ao teste de absorção e solubilidade e a outra metade, aos testes de dureza Shore A e alteração de cor. Todas as amostras foram submetidas à 2000 ciclos de termociclagem. O Dentusil apresentou os seguintes valores: Shore A (40,50); ΔE (0,83); absorção (0,30); solubilidade (0,01). Já o Trusoft apresentou os seguintes valores: Shore A (18,50); ΔE (3,92); absorção (1,48); solubilidade (1,26). O UfiGel P e SC apresentaram resultados semelhantes e intermediarios para os 3 testes. Portanto conclui-se que todas as propriedades estão intimamente relacionadas e que quanto maior for a dureza inicial do material, menor será a absorção e solubilidade e consequentemente menor será a alteração de cor.
dc.description.abstractThe purpose of this study was to investigate absorption, solubility, hardness and colour change of 4 soft liners after thermocycling. A resin base (Trusoft) and three silicone base (Dentusil, Ufi Gel P e Ufi Gel SC) were used on this research. A total of eighty samples were manufactured: forty for absorption and solubility test and forty for both hardness and colour change tests. All samples were subjected to 2000 hours of thermocycling. Dentusil showed the following values: Shore A hardness (40.50), colour change (ΔE=0.83), absorption (0.30) and solubility (0.01). Trusoft, on the other hand, showed the following values: Shore A hardness (18.50), colour change (ΔE=3.92), absorption (1.48) and solubility (1.26). Both UfiGel P and SC showed similar results for all three tests. All properties are linked and as big is the initial hardness, small will be both absorption and solubility and consequently small will be the colour change.
dc.languagepor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rightsAcesso aberto
dc.sourceAleph
dc.subjectCor
dc.subjectAbsorção
dc.subjectSolubilidade
dc.subjectSilicones
dc.subjectDureza
dc.subjectHardness
dc.subjectColor
dc.subjectAbsorption
dc.subjectSolubility
dc.titleO uso da termociclagem na avaliação da absorção, solubilidade, dureza e alteração de cor de reembasadores resilientes
dc.typeTesis


Este ítem pertenece a la siguiente institución