dc.description.abstractO princípio de funcionamento de um sistema gas-lift é bastante simples, baseando-se na injeção de um gás inerte próximo à extremidade submersa de um tubo utilizado para ascensão do líquido (riser). Esse sistema tem sido utilizado em diversos setores da indústria, dentre os quais se destaca o setor petroquímico. Apesar de ter sido concebido há mais de um século, e a despeito do considerável número de artigos publicados sobre o assunto, vários aspectos relativos às características do escoamento bifásico dentro do riser e ao funcionamento do sistema são, ainda, pouco conhecidos. No presente trabalho, um sistema air-lift de pequeno porte foi inteiramente desenvolvido e testado, permitindo observar o comportamento do sistema quando submetido a variações na vazão de ar, na razão de submersão e na geometria do injetor – contendo três (3F) ou quinze furos (15F). Ensaios de visualização foram conduzidos, possibilitando a caracterização do escoamento bifásico no interior do riser. Medições experimentais foram, também, realizadas para a obtenção da eficiência e das curvas características do sistema. Os resultados quantitativos foram interpretados em associação com imagens estáticas do escoamento, capturadas com uma câmera fotográfica digital, e com imagens dinâmicas, tomadas com o auxílio de uma filmadora de alta velocidade. A partir destas imagens, foi possível, ainda, a estimativa de alguns importantes parâmetros característicos do escoamento pistonado, associados ao deslocamento da chamada bolha de Taylor. Os dados assim obtidos foram comparados com valores oriundos de correlações empíricas propostas por outros autores, apresentando boa concordância. Com relação aos resultados quantitativos, observou-se que, sob determinadas condições de operação, o injetor 3F é capaz de atribuir ao sistema um rendimento significativamente maior...
dc.description.abstractThe operation principle of a gas-lift system is very simple: it is based on the injection of an inert gas close to the immersed edge of a tube, which is used for the rising of the liquid (riser). This system has been used in several industrial areas and more often in the petrochemical industry. Despite the fact that it was conceived over a century ago and that there have been a considerable amount of articles published on the subject, several aspects concerning the two-phase flow characteristics inside the riser as well as its operational system are still not very well known. In the present work, a small size air-lift system was thoroughly developed and tested, which facilitated the visualization of the system behavior when submitted to variations in the air flow, the immersion ratio and the injector geometry – containing three (3H) or fifteen holes (15H). Observation experiments were carried out making it possible to characterize the two-phase flow inside the riser. Experimental measurements were also taken in order to obtain the system characteristic efficiency and slopes. The quantitative results were analyzed together with the statistic images of the flow - taken by a digital photo camera, and with the dynamic images – taken by a high-speed filming camera. Through these images, it was also possible to estimate some important characteristic parameters of the slug flow associated to the displacement of the so-called Taylor bubble. The data obtained this way were compared to the figures originated from experimental correlations proposed by other authors, and they showed a fine agreement. Regarding the quantitative results, it was observed that under certain operation conditions the 3F injector is able to give the system a significantly greater efficiency than when the 15F injector is used
dc.languagepor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rightsAcesso aberto
dc.sourceAleph
dc.subjectEscoamento bifasico
dc.subjectVisualização de fluxo
dc.subjectEscoamento pistonado
dc.subjectVelocidade de bolha
dc.subjectSistema gas-lift
dc.subjectGas-lift system
dc.subjectTwo-phase flow
dc.subjectSlug flow
dc.subjectTaylor bubble
dc.subjectBubble velocity
dc.subjectFlow visualization
dc.titleEstudo experimental do funcionamento de um sistema gas-lif
dc.typeTesis