dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Estadual de Campinas (UNICAMP)
dc.date.accessioned2014-05-27T11:30:15Z
dc.date.available2014-05-27T11:30:15Z
dc.date.created2014-05-27T11:30:15Z
dc.date.issued2013-08-26
dc.identifierRevista da Educacao Física, v. 24, n. 1, p. 111-119, 2013.
dc.identifier0103-3948
dc.identifier1983-3083
dc.identifierhttp://hdl.handle.net/11449/76334
dc.identifier2-s2.0-84882438856
dc.identifier2-s2.0-84882438856.pdf
dc.description.abstractO objetivo deste estudo foi determinar, em mesatenistas bem treinados, as aptidões aeróbia e anaeróbia. Participaram do presente estudo oito mesatenistas brasileiros treinados do sexo masculino (18±2 anos). Os sujeitos foram submetidos a um teste incremental específico para determinação do consumo pico de oxigênio (VO2PICO), intensidade associada ao VO2PICO (iVO2PICO) e do ponto de compensação respiratório (PCR) e a dois testes de esforço repetitivo, sendo o teste de RAST e o índice anaeróbio alático (IAA), para determinação dos índices anaeróbios. O VO2PICO correspondeu a 50,5±4,4ml kg-1 min-1 , a iVO2PICO a 52,1±9,6 bolas min-1 e o PCR a 44,9±8,0 bolas min-1. No RAST, a potência pico (PP) e a potência média (PM) relativa corresponderam a 9,0±1,3W kg-1 e 7,0±0,9W kg-1, respectivamente, enquanto que o IAA foi 1,14±0,51 mM/m s-1 . Esses valores de VO2PICO e dos parâmetros anaeróbios quando comparados a valores de outros esportes com raquetes caracterizaram que mesatenistas brasileiros treinados apresentam potência aeróbia moderada e potência anaeróbia é baixa.
dc.description.abstractThe purposes of this study were to determine the aerobic conditioning and anaerobic conditioning in trained table tennis players. Eigth Brazilian male table tennis players (18±2 years) participated of the study. Subjects performed graded exercise test in specific procedure to measure peak oxygen uptake (V̇ O2PEAK), intensity associated at V̇ O 2PEAK (iV̇ O2PEAK) and respiratoty conpensation point (RCP), and two repeated-sprint abilit tests (i.e., RAST and alactic anaerobic índex (AAI)), which were considered as anaerobic parameters. V̇ O2PEAK corresponded to 50.5±4.4ml kg-1 min -1, iV̇ O2PEAK to 52.1±9.6balls min -1 e o RCP 44.9±8.0balls min-1. Peak power (PP) and mean power (MP) relative to body mass (PPr and MPr, respectively) measured during RAST were 9.0±1.3W kg-1 and 7.0±0.9W kg -1, respectively, whereas AAI (i.e., ratio of blood lactate and average speed) was 1.14±0.51mM/m s-1. Thus, we can conclude that trained Brazilian table tennis players have moderated aerobic power, low anaerobic conditioning.
dc.languagepor
dc.relationRevista da Educacao Fisica
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectPotência anaeróbia
dc.subjectCapacidade aeróbia
dc.subjectConsumo pico de oxigênio
dc.subjectÍndice anaeróbio alático
dc.subjectRAST
dc.subjectAnaerobic power
dc.subjectAerobic capacity
dc.subjectPeak oxygen uptake
dc.subjectA-lactic anaerobic índex
dc.subjectRAST
dc.titleCaracterísticas aeróbias e anaeróbias de mesatenistas brasileiros treinados
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución