dc.contributorUniversidade Estadual de Campinas (UNICAMP)
dc.contributorItaúna University
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-27T11:23:44Z
dc.date.available2014-05-27T11:23:44Z
dc.date.created2014-05-27T11:23:44Z
dc.date.issued2008-12-01
dc.identifierBrazilian Dental Journal, v. 19, n. 4, p. 348-353, 2008.
dc.identifier0103-6440
dc.identifier1806-4760
dc.identifierhttp://hdl.handle.net/11449/70713
dc.identifier10.1590/S0103-64402008000400011
dc.identifierS0103-64402008000400011
dc.identifier2-s2.0-63249129569
dc.identifier2-s2.0-63249129569.pdf
dc.description.abstractThis study evaluated the effect of microwave energy on the hardness, impact strength and flexural strength of the Clássico, Onda-Cryl and QC-20 acrylic resins. Aluminum die were embedded in metallic or plastic flasks with type III dental stone, in accordance with the traditional packing technique. A mixing powder/liquid ratio was used according to the manufacturer's instructions. After polymerization in water batch at 74°C for 9 h, boiling water for 20 min or microwave energy at 900 W for 10 min, the specimens were deflasked after flask cooling at room temperature, and submitted to finishing. Specimens non-disinfected and disinfected by microwave irradiation were submitted to hardness, impact and flexural strength tests. Each specimen was immersed in distilled water and disinfected in a microwave oven calibrated to 650 W for 3 min. Knoop hardness test was performed with 25 g load for 10 s, impact test was carried out using the Charpy system with 40 kpcm, and 3-point bending test with a crosshead speed of 0.5 mm/min until fracture. Data were submitted to statistical analysis by ANOVA and Tukey's test (α=0.05). Disinfection by microwave energy decreased the hardness of Clássico and Onda-Cryl acrylic resins, but no effect was observed on the impact and flexural strength of all tested resins.
dc.languageeng
dc.relationBrazilian Dental Journal
dc.relation0,476
dc.rightsAcesso aberto
dc.sourceScopus
dc.subjectAcrylic resin
dc.subjectFlexural strength
dc.subjectHardness
dc.subjectImpact
dc.subjectMicrowave disinfection
dc.subjectacrylic acid resin
dc.subjectdental care
dc.subjectdisinfection
dc.subjectequipment
dc.subjecthardness
dc.subjectmaterials testing
dc.subjectmethodology
dc.subjectmicrowave radiation
dc.subjectpliability
dc.subjectradiation exposure
dc.subjectAcrylic Resins
dc.subjectDental Stress Analysis
dc.subjectDisinfection
dc.subjectEquipment Contamination
dc.subjectMaterials Testing
dc.subjectMicrowaves
dc.subjectPliability
dc.titleEffect of microwave disinfection on physical and mechanical properties of acrylic resins
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución