dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-27T11:21:08Z | |
dc.date.available | 2014-05-27T11:21:08Z | |
dc.date.created | 2014-05-27T11:21:08Z | |
dc.date.issued | 2004-08-30 | |
dc.identifier | Journal of the Brazilian Chemical Society, v. 15, n. 3, p. 366-371, 2004. | |
dc.identifier | 0103-5053 | |
dc.identifier | http://hdl.handle.net/11449/67834 | |
dc.identifier | 10.1590/S0103-50532004000300005 | |
dc.identifier | S0103-50532004000300005 | |
dc.identifier | WOS:000221883800004 | |
dc.identifier | 2-s2.0-4143086075 | |
dc.identifier | 2-s2.0-4143086075.pdf | |
dc.identifier | 6981448637456391 | |
dc.description.abstract | This work describes the synthesis and characterization of 2-aminothiazole modified silica gel (SiAT), and the results of a study of the adsorption and pre-concentration (in batch and using a flow-injection system coupled to an absorption atomic spectrometer) of Cu(II), Ni(II) and Pb(II) in aqueous medium. The adsorption capacities for each metal ions in mmol g -1 were: Cu(II)= 1.18, Ni(II)= 1.15 and Pb(II)= 1.10. The results obtained in the flow experiments showed a recovery of practically 100% of the metal ions adsorbed in a mini-column packed with 100 mg of SiAT, using 100 μL of 2.0 mol L -1 HCl solution as eluent. The sorption-desorption of the metal ions made possible the application of a flow-injection system for the pre-concentration and quantification by FAAS of metal ions at trace level in natural water samples digested and not digest by an oxidizing UV photolysis. | |
dc.language | eng | |
dc.relation | Journal of the Brazilian Chemical Society | |
dc.relation | 1.444 | |
dc.relation | 0,357 | |
dc.rights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | 2-aminothiazole modified silica gel | |
dc.subject | FAAS | |
dc.subject | Pre-concentration | |
dc.subject | Water samples | |
dc.subject | 2 aminothiazole derivative | |
dc.subject | copper | |
dc.subject | hydrochloric acid | |
dc.subject | lead | |
dc.subject | metal ion | |
dc.subject | nickel | |
dc.subject | silica gel | |
dc.subject | adsorption | |
dc.subject | aqueous solution | |
dc.subject | atomic adsorption spectrometer | |
dc.subject | batch process | |
dc.subject | chemical analysis | |
dc.subject | chemical modification | |
dc.subject | concentration (parameters) | |
dc.subject | desorption | |
dc.subject | flow injection analysis | |
dc.subject | oxidation | |
dc.subject | photolysis | |
dc.subject | quantitative analysis | |
dc.subject | spectrometer | |
dc.subject | synthesis | |
dc.subject | ultraviolet radiation | |
dc.subject | water sampling | |
dc.title | Determination of Cu, Ni and Pb in Aqueous Medium by FAAS after Pre-Concentration on 2-Aminothiazole Modified Silica Gel | |
dc.type | Artículos de revistas | |