dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal de São Carlos (UFSCar)
dc.date.accessioned2014-05-27T11:21:07Z
dc.date.available2014-05-27T11:21:07Z
dc.date.created2014-05-27T11:21:07Z
dc.date.issued2004-07-21
dc.identifierIndustrial and Engineering Chemistry Research, v. 43, n. 15, p. 4140-4148, 2004.
dc.identifier0888-5885
dc.identifierhttp://hdl.handle.net/11449/67801
dc.identifier10.1021/ie030759u
dc.identifierWOS:000222738000018
dc.identifier2-s2.0-3242686914
dc.description.abstractHeat-transfer studies were carried out in a packed bed of glass beads, cooled by the wall, through which air percolated. Tube-to-particle diameter ratios (D/dp) ranged from 1.8 to 55, while the air mass flux ranged from 0.204 to 2.422 kg/m2·s. The outlet bed temperature (TL) was measured by a brass ring-shaped sensor and by aligned thermocouples. The resulting radial temperature profiles differed statistically. Angular temperature fluctuations were observed through measurements made at 72 angular positions. These fluctuations do not follow a normal distribution around the mean for low ratios D/dp. The presence of a restraining screen, as well as the increasing distance between the temperature measuring device and the bed surface, distorts TL. The radial temperature profile at the bed entrance (T0) was measured by a ring-shaped sensor, and T 0 showed to be a function of the radial position, the particle diameter, and the fluid flow rate.
dc.languageeng
dc.relationIndustrial and Engineering Chemistry Research
dc.relation3.141
dc.relation0,978
dc.rightsAcesso restrito
dc.sourceScopus
dc.subjectCooling
dc.subjectFlow of fluids
dc.subjectGlass
dc.subjectHeat transfer
dc.subjectThermocouples
dc.subjectAir flow
dc.subjectTemperature profiles
dc.subjectPacked beds
dc.subjectglass
dc.subjectmicrosphere
dc.subjectair
dc.subjectairflow
dc.subjectheat transfer
dc.subjectmathematical analysis
dc.subjectmodel
dc.subjectpacked bed
dc.subjectair mass flux
dc.subjectanalysis
dc.subjectexperiment
dc.subjectflow rate
dc.subjectmass
dc.subjectmeasurement
dc.subjectpacked bed reactor
dc.subjectparticle size
dc.subjectradial temperature
dc.subjectsensor
dc.subjecttemperature
dc.subjecttube
dc.subjecttube to particle diameter ratio
dc.titleExperimental analysis of heat transfer in packed beds with air flow
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución