dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal do Rio Grande do Sul (UFRGS)
dc.date.accessioned2014-05-20T15:26:43Z
dc.date.available2014-05-20T15:26:43Z
dc.date.created2014-05-20T15:26:43Z
dc.date.issued1999-07-01
dc.identifierJournal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 20, n. 3, p. 413-417, 1999.
dc.identifier0731-7085
dc.identifierhttp://hdl.handle.net/11449/36822
dc.identifier10.1016/S0731-7085(98)00102-2
dc.identifierWOS:000080819800001
dc.description.abstractA specific and sensitive high-performance liquid chromatographic procedure was developed for the assay of sparfloxacin in raw material and tablets. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The method validation yielded good results and included the range, linearity, precision, accuracy, specificity and recovery. This method can also be applied to stability studies. (C) 1999 Elsevier B.V. B.V. All rights reserved.
dc.languageeng
dc.publisherElsevier B.V.
dc.relationJournal of Pharmaceutical and Biomedical Analysis
dc.relation2.831
dc.relation0,919
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectfluoroquinolone
dc.subjectHPLC
dc.subjectquality control
dc.subjectsparfloxacin
dc.titleA high-performance liquid chromatographic assay for sparfloxacin
dc.typeArtículos de revistas