dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:22:39Z
dc.date.available2014-05-20T15:22:39Z
dc.date.created2014-05-20T15:22:39Z
dc.date.issued2002-09-05
dc.identifierJournal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 30, n. 2, p. 279-284, 2002.
dc.identifier0731-7085
dc.identifierhttp://hdl.handle.net/11449/33596
dc.identifier10.1016/S0731-7085(02)00339-4
dc.identifierWOS:000178465900013
dc.identifier0072173018005712
dc.description.abstractA versatile voltammetric method for quantitative determination of fenbendazole (FBZ) in commercial tablets has been proposed, where direct dissolution of tablets is carried out in 0.1 mol l(-1) tetrabutylamoniun tetrafluorborate containing dimethylformamide solutions. Linear sweep (LSV), square wave (SWV) and differential pulse (DPV) voltammetry techniques were applied to study FBZ at a glassy carbon electrode, exhibiting a well defined irreversible oxidation peak at 1.15 V vs. SCE. This methodology allows a precise quantitative determination of FBZ presenting detection limits of 5.2 x 10(-5) (LSV), 5.0 x 10(-6) (DPV) and 5.0 x 10(-5) mol l(-1) (SWV). (C) 2002 Elsevier B.V. B.V. All rights reserved.
dc.languageeng
dc.publisherElsevier B.V.
dc.relationJournal of Pharmaceutical and Biomedical Analysis
dc.relation2.831
dc.relation0,919
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectfenbendazole
dc.subjectanthelmintic
dc.subjectvoltammetric determination
dc.titleVoltammetric determination of fenbendazole in veterinarian formulations
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución