dc.contributorUniversidade de São Paulo (USP)
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal do Pampa (UNIPAMPA)
dc.date.accessioned2014-05-20T15:13:15Z
dc.date.available2014-05-20T15:13:15Z
dc.date.created2014-05-20T15:13:15Z
dc.date.issued2009-09-01
dc.identifierRevista Brasileira de Geofísica. Sociedade Brasileira de Geofísica, v. 27, n. 3, p. 389-399, 2009.
dc.identifier0102-261X
dc.identifierhttp://hdl.handle.net/11449/28716
dc.identifier10.1590/S0102-261X2009000300007
dc.identifierS0102-261X2009000300007
dc.identifierS0102-261X2009000300007.pdf
dc.identifier9086857312391080
dc.identifier0000-0002-6949-6679
dc.description.abstractNeste trabalho são apresentados os resultados da aplicação do método da eletrorresistividade para delimitação de áreas potencialmente impactadas por necrochorume no cemitério municipal de Vila Rezende, Piracicaba - SP. Os resultados indicam uma profundidade do nível freático entre 3,1 e 5,1 m na época de estiagem, com duas direções de fluxo subterrâneo: uma a SW e outra a SE. Indicam ainda condições desfavoráveis, em subsuperfície, para percolação do necrochorume, mas favoráveis ao fenômeno de saponificação dos cadáveres. As prováveis plumas de contaminação têm as mesmas direções do fluxo subterrâneo. A provável pluma a SE se prolonga para fora dos limites do cemitério. A localização das anomalias condutivas e das prováveis plumas de contaminação demonstrou que a contaminação tem ligação com a profundidade do nível freático e com o tempo de sepultamento. O método da eletrorresistividade demonstrou ser um instrumento importante para avaliação da qualidade ambiental em cemitérios.
dc.description.abstractThis paper presents the results of the application of electrical resistivity method in the delineation of areas potentially impacted by necrochorume in Vila Rezende's municipal cemetery, Piracicaba - SP (Brazil). The results indicate a depth of water table among 3.1 and 5.1 m in drought, with two flow directions: a SW and another to the SE. Also indicate unfavorable conditions in subsurface to percolation of necrochorume but favorable to the corpses phenomenon saponification. The probable contamination plumes have the same directions of the groundwater flow. The probable plume is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time. The electrical resistivity method has proved to be an important tool for assessing the environmental quality in cemeteries.
dc.languagepor
dc.publisherSociedade Brasileira de Geofísica
dc.relationRevista Brasileira de Geofísica
dc.rightsAcesso aberto
dc.sourceSciELO
dc.subjecteletrorresistividade
dc.subjectsaponificação
dc.subjectcemitério
dc.subjectnecrochorume
dc.subjectpluma de contaminação
dc.subjectelectrical resistivity
dc.subjectsaponification
dc.subjectcemetery
dc.subjectnecrochorume
dc.subjectcontamination plume
dc.titleEmprego do método da eletrorresistividade no estudo da contaminação subterrânea do cemitério municipal de Vila Rezende, Piracicaba - SP
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución