dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.contributor | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T14:17:27Z | |
dc.date.available | 2014-05-20T14:17:27Z | |
dc.date.created | 2014-05-20T14:17:27Z | |
dc.date.issued | 2007-09-01 | |
dc.identifier | Engenharia Sanitaria e Ambiental . ABES , v. 12, n. 3, p. 273-283, 2007. | |
dc.identifier | 1413-4152 | |
dc.identifier | http://hdl.handle.net/11449/25225 | |
dc.identifier | 10.1590/S1413-41522007000300007 | |
dc.identifier | S1413-41522007000300007 | |
dc.identifier | S1413-41522007000300007.pdf | |
dc.identifier | 9408665052901005 | |
dc.identifier | 0000-0002-1573-3747 | |
dc.description.abstract | O artigo apresenta um método proposto para determinação de tamanho de microbolhas de ar (DTMB) em sistemas de tratamento de água por flotação por ar dissolvido (FAD), utilizando a análise de imagem digital. Adicionalmente, é apresentado um estudo de caso com emprego de unidade em escala piloto. A aquisição das imagens foi realizada com uma câmera digital de 5.1MPixel, acoplada a conjunto de lentes. As imagens de microbolhas foram adquiridas em sistema com escoamento contínuo para eliminar as interferências causadas pela captura de amostras. O tratamento e obtenção das feições foram realizadas com o programa (freeware) ImageTool. Os resultados apresentaram coerência com os valores reportados na literatura utilizando métodos tradicionais. O sistema mostrou-se eficaz e o método desenvolvido pode constituir ferramenta útil para estudos em outras subáreas de conhecimento. | |
dc.description.abstract | An image analysis method proposed for assessing bubble size distribution applied to dissolved air flotation (DAF) systems for drinking water treatment is presented. Further, a pilot plant investigation is presented. A digital camera together with a group of lens was used. In order to eliminate samples interferences the images were captured in a continuous flow system working in steady state. The freeware ImageTool was applied for treating and obtaining size distribution. Results were presented in good relationship with traditional methods. The role image system showed to be efficient for image capturing and the proposed method may be an useful tool to other researches areas. | |
dc.language | por | |
dc.publisher | ABES | |
dc.relation | Engenharia Sanitária e Ambiental | |
dc.relation | 0.290 | |
dc.relation | 0,218 | |
dc.rights | Acesso aberto | |
dc.source | SciELO | |
dc.subject | Partículas | |
dc.subject | análise de imagem | |
dc.subject | tratamento de água e flotação por ar dissolvido | |
dc.subject | Particle size | |
dc.subject | particle size distribution | |
dc.subject | water and wastewater treatment | |
dc.title | Método para determinação de distribuição de tamanho de microbolhas (DTMB) em sistemas flotação (FAD) para tratamento de águas utilizando a análise de imagem digital | |
dc.type | Artículos de revistas | |