dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2013-09-30T18:30:05Z
dc.date.accessioned2014-05-20T13:43:43Z
dc.date.available2013-09-30T18:30:05Z
dc.date.available2014-05-20T13:43:43Z
dc.date.created2013-09-30T18:30:05Z
dc.date.created2014-05-20T13:43:43Z
dc.date.issued2010-01-01
dc.identifierJournal of Craniofacial Surgery. Philadelphia: Lippincott Williams & Wilkins, v. 21, n. 1, p. 182-187, 2010.
dc.identifier1049-2275
dc.identifierhttp://hdl.handle.net/11449/15276
dc.identifier10.1097/SCS.0b013e3181c50eb8
dc.identifierWOS:000273902400042
dc.identifier4438747643373395
dc.description.abstractIn implant therapy, a peri-implant bone resorption has been noticed mainly in the first year after prosthesis insertion. This bone remodeling can sometimes jeopardize the outcome of the treatment, especially in areas in which short implants are used and also in aesthetic cases. To avoid this occurrence, the use of platform switching (PS) has been used. This study aimed to evaluate the biomechanical concept of PS with relation to stress distribution using two-dimensional finite element analysis. A regular matching diameter connection of abutment-implant (regular platform group [RPG]) and a PS connection (PS group [PSG]) were simulated by 2 two-dimensional finite element models that reproduced a 2-piece implant system with peri-implant bone tissue. A regular implant (prosthetic platform of 4.1 mm) and a wide implant (prosthetic platform of 5.0 mm) were used to represent the RPG and PSG, respectively, in which a regular prosthetic component of 4.1 mm was connected to represent the crown. A load of 100 N was applied on the models using ANSYS software. The RPG spreads the stress over a wider area in the peri-implant bone tissue (159 MPa) and the implant (1610 MPa), whereas the PSG seems to diminish the stress distribution on bone tissue (34 MPa) and implant (649 MPa). Within the limitation of the study, the PS presented better biomechanical behavior in relation to stress distribution on the implant but especially in the bone tissue (80% less). However, in the crown and retention screw, an increase in stress concentration was observed.
dc.languageeng
dc.publisherLippincott Williams & Wilkins
dc.relationJournal of Craniofacial Surgery
dc.relation0.772
dc.relation0,448
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectDental implants
dc.subjectplatform switching
dc.subjectimplant supported prosthesis
dc.subjectfinite element analysis
dc.subjectstress distribution
dc.subjectcrestal bone loss
dc.titleImplant Platform Switching: Biomechanical Approach Using Two-Dimensional Finite Element Analysis
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución