dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T13:23:36Z
dc.date.available2014-05-20T13:23:36Z
dc.date.created2014-05-20T13:23:36Z
dc.date.issued2011-10-01
dc.identifierRevista Panamericana de Salud Publica-pan American Journal of Public Health. Washington: Pan Amer Health Organization, v. 30, n. 4, p. 309-316, 2011.
dc.identifier1020-4989
dc.identifierhttp://hdl.handle.net/11449/7138
dc.identifier10.1590/S1020-49892011001000004
dc.identifierS1020-49892011001000004
dc.identifierWOS:000299527200004
dc.identifier1055911386902390
dc.description.abstractObjective. Measure physical therapists' exposure to the electric and magnetic fields produced by 17 shortwave diathermy devices in physical therapy clinics in the city of Presidente Prudente, São Paulo State, Brazil. Compare the observed values with the exposure levels recommended by the International Commission on Non-ionizing Radiation Protection (ICNIRP). Observe the efficacy of Faraday cages as a means of protecting physical therapists from exposure to oscillating electric and magnetic fields.Methods. Electric and magnetic field measurements were taken at four points during actual physical therapy sessions: in proximity to the operator's pelvis and head, the devices' electrical cables, and the electrodes. The measuring equipment was a Wandel & Goltermann EMR-200.Results. The values obtained in proximity to the electrodes and cables were 10 to 30 times higher than ICNIRP's recommended occupational reference levels. In the shortwave diathermy treatment rooms with Faraday cages, the fields were even higher than in treatment rooms not so equipped-principally the magnetic field, where the values were more than 100 times higher than the ICNIRP exposure limit.Conclusions. The electric and magnetic field intensities obtained in this study are generally above the exposure levels recommend in ICNIRP standards. It was also observed that the Faraday cage offers physical therapists no protection, and instead, increases their level of exposure.
dc.languagepor
dc.publisherPan Amer Health Organization
dc.relationRevista Panamericana de Salud Publica - Pan American Journal of Public Health
dc.relation0.784
dc.relation0,452
dc.rightsAcesso aberto
dc.sourceWeb of Science
dc.subjectOccupational exposure
dc.subjectradiation, nonionizing
dc.subjectphysical therapy
dc.subjectelectromagnetic fields
dc.subjectdiathermy
dc.subjectshort-wave therapy
dc.subjectBrazil
dc.titleOccupational exposure of physical therapists to electric and magnetic fields and the efficacy of Faraday cages
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución